Diagram 34 <strong>Water</strong> Heater Fault Finding<br />

Expansion Valve Faults<br />

EXPANSION RELIEF<br />

VALVE DISCHARG ES<br />

IS<br />

DISCHARGE<br />

INTERMITTENT<br />

YES<br />

CHECK DHW<br />

EXPANSION<br />

VESSEL CHARGE<br />

PRESSURE IS 3.5 BAR<br />

NO<br />

IS<br />

DISCHARGE<br />

CONTINUOUS<br />

YES<br />

CHECK COLD W ATER<br />

COM BIVALVE<br />

PRESSURE REDUCER<br />

CONTROLS AT 3.5BAR<br />

CHECK EXPANSION<br />

VALVE O PERATION.<br />

Diagram 35 <strong>Water</strong> Heater Fault Finding<br />

Temperature & Pressure Relief Valve<br />

Faults<br />

TEM PERATURE /<br />

PRESSURE RELIEF<br />

VALVE D ISCHARG ES<br />

IS<br />

DISCHARGE<br />

TEM PERATURE VERY<br />

o<br />

HOT (>85C )<br />

YES<br />

THERM AL CO NTRO L<br />

FAILUR E.C HECK<br />

THERM O STAT<br />

OPERATION<br />

NO<br />

IS<br />

DISCHARGE<br />

AT NO R M AL<br />

OPERATING TEMP<br />

o<br />

(UP TO 70C)<br />

YES<br />

TEM PERATURE /<br />

PRESSURE RELIEF<br />

VALVE FAU LT.<br />

REPLACE.<br />