DOMESTIC BOOSTER <strong>SETS</strong> WITH ACTIVE DRIVER 1<br />

PLUS:<br />

- Constant pressure<br />

- Noiselessness<br />

- Reduced running costs<br />

- Reduced water consumption<br />

- Compact size (no vessels needed)<br />

- Reduced Maintenance.<br />

- Dry running protection<br />

The units with Active Driver 1 have been especially designed and manufactured to satisfy requirements for constant<br />

pressure in modern systems. Constant pressure-controlled systems are suitable for:<br />

Aqueducts – Irrigation – Industry – Hotel installations – Domestic installations – Thermal baths.<br />

The design of the system features flexibility, reliability and user-friendliness.<br />

ABOUT ACTIVE DRIVER 1<br />

The Active Driver 1 unit is a comprehensive device that includes hydraulic system connections, a pressure sensor, a<br />

flow sensor and an electronic frequency converter (inverter). When fitted to the delivery of each pump, the Active Driver<br />

1 regulates the rotation speed of the electric pump to which it is connected maintaining a constant pressure in relation<br />

to the flow rate variation of the water. The water that flows through the Active Driver 1 also helps to cool the internal<br />

electronic components.<br />

OPERATION<br />

When pressure drops because of a water request, only one pump runs in order to satisfy water need. The second and<br />

third pumps start operation in cascade when the first one reaches maximum velocity. The user can adjust the pressure<br />

of the pumps by means of the two + and – buttons on the Active Driver 1 (the pumps are set as standard at the same<br />

pressure value).<br />

The pumps cut-out under the following conditions:<br />

- pump overcurrent<br />

- dry running<br />

- low supply voltage<br />

- max. pressure value exceeded (adjustable)<br />

- Active driver 1 electronic components overheating.<br />

Two or three pump boosters with Active Driver 1 are supplied along with a safety control unit<br />

with magneto-thermal cut-out and power supply input terminal board.<br />

ACTIVE DRIVER 1 DISPLAYED FUNCTIONS<br />

- Pump operating frequency (Hz)<br />

- Instantaneous pressure (bar)<br />

- Pump absorbed current (ampere)<br />

- Operating alarms<br />

ACTIVE DRIVER 1 EXTERNAL CONNECTIONS<br />

Inputs: pump cut-out, pressure-switch / float against dry-running.<br />

Outputs: two potential free contacts for alarm/stop and pump running signalling.<br />

55<br />

®