The performance curves are based on the kinematic viscosity values = 1 mm 2 /s and density equal to 1000 Kg/m 3 . Curve tolerance according to ISO 9906.<br />

3 KVCX <strong>SETS</strong><br />

Liquid temperature range:<br />

Maximum ambient temperature:<br />

Max flow rate: 36 m 3 /h<br />

Overall performance – THREE pumps working simultaneously.<br />

The performance of groups with smaller pumps (e.g. 3KVCX 20/50) is achieved through the setting of the Active Driver 1 unit.<br />

MODEL<br />

3 KVCX AD 30/50<br />

3 KVCX AD 55/50<br />

3 KVCX AD 75/50<br />

3 KVCX AD 30/80<br />

3 KVCX AD 45/80<br />

3 KVCX AD 65/80<br />

3 KVCX AD 35/120<br />

3 KVCX AD 60/120<br />

A B C<br />

D<br />

H max H1 H3 DNA DNM<br />

PACKAGING DIMENSIONS<br />

L/A L/B H<br />

VOLUME<br />

m 3<br />

570 840 300 185 857 120 664 2” 1 / 2 2” 1 / 2 1000 610 1000 0,61 131<br />

570 840 300 185 912 120 719 2” 1 / 2 2” 1 / 2 1000 610<br />

C<br />

1000 0,61 141<br />

570 840 300 185 1005 120 812 2” 1 / 2 2” 1 / 2 1000 610 1000 0,61 150<br />

570 840 300 185 912 120 719 2” 1 / 2 2” 1 / 2 1000 610 1000 0,61 136<br />

570 840 300 185 1005 120 812 2” 1 / 2 2” 1 / 2 1000 610 1000 0,61 150<br />

570 840 300 185 1032 120 839 2” 1 / 2 2” 1 / 2 1000 610 1000 0,61 156<br />

570 840 300 185 857 120 664 DN80 DN80 1000 610 1000 0,61 150<br />

570 840 300 185 912 120 719 DN80 DN80 1000 610 1000 0,61 162<br />

WEIGHT<br />

Kg<br />

VOLTAGE P2 NOMINAL In (set) FLOW RATE MAX PRESSURE STANDARD PRES-<br />

MODEL<br />

OBTAINABLE SURE<br />

50 Hz kW HP A m 3 /h BAR BAR<br />

3 KVCX AD 30/50 1x220-400 V~ 3x0,55 3x0,75 3x4,1 13,5-1 4 3,5<br />

3 KVCX AD 55/50 3x400 V~ + N * 3x1 3x1,36 3x7,6 13,5-1 6,5 5,5<br />

3 KVCX AD 75/50 3x400 V~ + N * 3x1,5 3x2 3x10,7 13,5-1 9,2 8<br />

3 KVCX AD 30/80 3x400 V~ + N * 3x0,8 3x1,1 3x6,5 21-2 4,5 3,5<br />

3 KVCX AD 45/80 3x400 V~ + N * 3x1,1 3x1,5 3x9,3 21-2 6,6 5,5<br />

3 KVCX AD 65/80 3x400 V~ + N * 3x2,2 3x3 3x12 21-2 9,2 8<br />

3 KVCX AD 35/120 3x400 V~ + N * 3x1,1 3x1,5 3x10,4 33-2 4,4 3,5<br />

3 KVCX AD 60/120 3x400 V~ + N * 3x2,2 3x3 3x16,1 33-2 7,5 6<br />

The units are supplied packed in a strong cardboard box with a wooden pallet and installation and maintenance instructions.<br />

* Available on request with single-phase power supply (1x220-240 V~).<br />

75<br />

®