ADVANTAGES<br />

Constant pressure – Reduced running costs – No water hammering – Compact size<br />

Reduced maintenance - Reduced power factor correction – Reduced water consumption.<br />

CONSTRUCTIONAL CHARACTERISTICS<br />

The inverter-controlled units comprise two or three centrifugal pumps totally assembled on a galvanised steel bedplate<br />

that is tested and ready for fitting.<br />

Including shut-off and non-return valves for each pump, galvanised steel suction and delivery manifolds, expansion<br />

tanks, pressure transducer, emergency pressure switches, control panel with inverter.<br />

ELECTRICAL PANEL WITH INVERTER<br />

The Inverter continuously adjusts the speed of rotation of an electric pump in order to maintain constant pressure at a<br />

variable flow.<br />

The other electric pumps support the first by intervening in a cascade sequence following an increase in water<br />

requirements; during this phase, the Inverter works in the modulation mode.<br />

HYDROCONTROLLER manages the Inverter-commanded pump exchange system and alternates the order in<br />

which they start in order to ensure that each pump is used as much as the others.<br />