System<br />

Introduction<br />

The system chapter describes the architecture, the dimensions, the quantities and different<br />

types of components used within this system.<br />

Architecture<br />

General<br />

The controller in this application is a M238 <strong>Logic</strong> controller. The user controls the application<br />

using the Magelis HMI.<br />

The example application includes two functional safety options according to IEC 61508<br />

standards: an Emergency Stop function supervised by a Preventa <strong>AS</strong>ISAFEMON1 Safety<br />

Monitor (see the appropriate hardware manual), plus a second Preventa Safety Monitor to<br />

evaluate protective door sensors.<br />

The system consists of a control cabinet with the operator interface, a remote cabinet with<br />

the motor control and a subsystem for the field installation.<br />

The System includes an <strong>AS</strong>-<strong>Interface</strong> bus for communication between different devices.<br />

Layout<br />