Defining a<br />

Stop<br />

category<br />

8 Switch-off features are based<br />

on stop category 0 (undelayed<br />

switch-off).<br />

Note: If VSDs have been<br />

integrated, a delayed switch-off<br />

(stop category 1) can be selected,<br />

enabling the controlled ramping<br />

down of load disconnection.<br />

Confirm with OK.<br />

List of all<br />

configured<br />

functions of<br />

the Main<br />

safety<br />

monitor<br />

Check of<br />

Configuration<br />

9 The complete configuration of<br />

the monitor now looks like this.<br />

All conditions [32..34] must be<br />

true in order for the monitor to<br />

be enabled.<br />

10 Click on the check-mark icon<br />

to check the configuration. The<br />

result will appear in a separate<br />

window which will hide itself<br />

automatically.<br />