L-SUPPORT: CH 100-3-2,5mm<br />
MG-L: 02<br />
A)<br />
S-M WB-ST-CH100-3<br />
Thickness<br />
2,5 mm<br />
Height<br />
B)<br />
P y (KN)<br />
C)<br />
D)<br />
E)<br />
Width<br />
P x (KN)<br />
Items list:<br />
Function Type Thickness (.mm) Weight(kg) Art # HDG Art # SS #of Parts<br />
A) Welded Starter S-M WB-ST-CH100-3 4 1,2 1372514** 1372515 2<br />
B) Mekano Channel S-M CH100-3(*kg/m) 2,5 5,7* 1372504 1372505 1<br />
C) Splice Connector L S-M SC-L-CH100-3 4 0,2 1372510 1372511 4<br />
D) Self Lock Boltset S-M LS-NU-M10x20 10 0,05 1371980 1371983 44<br />
E) End Protection A-CH100-3 EP 2 0,1 1372506 1372507 1<br />
**) S-M WB-ST-CH100-3 is delivered in carbon steel quality.<br />
Load Capacity: Mekano Channel CH100-3-2,5(v) & CH100-3-2,5(h)<br />
Height(mm) Width(mm) Capacity DW P y (KN) Piping P y (KN) Piping P x (KN) Blast P y (KN) Blast P x (KN)<br />
600 200 10,8 4,0 1,6 12 6<br />
600 400 6 2,7 0,9 8 5,4<br />
600 600 3,3 1,7 0,6 5 5,4<br />
• Norsk Standard code NS3472/Eurocode 03/Norsok.<br />
• Capacity (KN) is calculated using point load on the centre of the horizontal <strong>support</strong>.<br />
• Piping: ULS – Ultimate Limit state – Load factor 1,3 – Material factor 1,15 on p = 210N/mm².<br />
• Other disciplines: SLS -. Load factor 1,0 – Material factor 1,15 on p = 210N/mm².<br />
• Deflection allowance piping: L/300 or 3 mm. Most conservative used.<br />
• Deflection allowance other disciplines: L/200<br />
• Section properties are based on effective values reduced for perforations.<br />
• For blast calculation p=450N/mm².<br />