Cantilever SUPPORT: CH60-2-6mm<br />
MG-C: 05<br />
S-M WB-200-CH50-2<br />
A)<br />
P y (KN)<br />
B)<br />
C)<br />
Width<br />
Thickness<br />
6 mm<br />
P x (KN)<br />
Items list:<br />
Function Type Thickness (.mm) Weight(kg) Art # HDG Art # SS #of Parts<br />
A) Welded Starter S-M WB-200-CH50-2 6 0,9 1302514** 1371698 2<br />
B) Mekano Channel S-M CH60-2(*kg/m) 6 5,3* 1371432 1371430 1<br />
C) Self Lock Boltset S-M LS-NU-M10x20 10 0,05 1371980 1371983 10<br />
**) S-M WB-200-CH50-2 is delivered in carbon steel quality.<br />
Load Capacity: Mekano Channel CH60-2<br />
Width(mm) Capacity DW P y (KN) Piping P y (KN) Piping P x (KN) Blast P y (KN) Blast P x (KN)<br />
200 4,4 3,4 1,1 10,5 10,0<br />
400 2,2 1,7 0,6 5,5 10,0<br />
600 1,5 1,1 0,4 3,5 10,0<br />
• Norsk Standard code NS3472/Eurocode 03/Norsok.<br />
• Capacity (KN) is calculated using point load.<br />
• Piping: ULS – Ultimate Limit state – Load factor 1,3 – Material factor 1,15 on p = 210N/mm².<br />
• Other disciplines: SLS -. Load factor 1,0 – Material factor 1,15 on p = 210N/mm².<br />
• Deflection allowance piping: L/300 or 3 mm. Most conservative used.<br />
• Deflection allowance other disciplines: L/200<br />
• Section properties are based on effective values reduced for perforations.<br />
• For blast calculation p=450N/mm².<br />
45