© <strong>Siemens</strong> AG 2007<br />
System Components and Accessories<br />
Extension plug<br />
■ Overview (continued)<br />
For particularly large AS-Interface networks the maximum possible<br />
cable length can be increased further by using repeaters.<br />
Please note that when a repeater and an extension plug / extension<br />
plug plus are used together, the series connection of repeaters<br />
is not possible. Hence the maximum possible distance<br />
from the master to a slave is 400 m and the absolute maximum<br />
cable length is 600 m. The parallel connection of repeaters for a<br />
star-shaped configuration with segments up to 200 m long respectively<br />
is possible.<br />
Master<br />
Extension<br />
Plug<br />
Power<br />
Supply<br />
Slave Slave Repeater<br />
Power<br />
Supply<br />
Power<br />
Supply<br />
Extension<br />
Plug<br />
Slave Slave Repeater<br />
Slave<br />
Extension<br />
Plug<br />
Slave<br />
200 m<br />
200 m<br />
600 m<br />
200 m<br />
G_NSA0_XX_00371<br />
Maximum network size with repeaters and extension plug (master at center of network)<br />
■ Benefits<br />
• Doubling of the cable length from 100 to 200 m per<br />
AS-Interface segment<br />
• More possibilities of use and greater freedom for plant<br />
planning through doubling of the AS-Interface segment<br />
• Notable reduction of network infrastructure costs for large<br />
networks<br />
■ Selection and ordering data<br />
3RK1 901-1MX00<br />
Accessories<br />
3RX9 801-0AA00<br />
1) For connection to the AS-Interface flat cable you need the<br />
AS-Interface M12 feeder, which must be ordered separately.<br />
Version<br />
AS-Interface Extension plugs 1)<br />
• Doubling of the cable length to 200 m per AS-Interface segment<br />
• Undervoltage monitoring signal by means of diagnostics LED<br />
AS-Interface Extension plugs plus 1)<br />
• Doubling of the cable length to 200 m per AS-Interface segment<br />
• Undervoltage monitoring signal by means of integral AS-Interface slave to<br />
AS-Interface master<br />
AS-Interface M12 feeders<br />
• For adaptation of shaped AS-Interface cable to a standard round cable<br />
• Insulation piercing method for connection of AS-Interface cable<br />
• M12 socket for connection of standard round cable<br />
• Degree of protection IP67<br />
• Enables in combination with repeaters a maximum range of up<br />
to 600 m for AS-Interface networks (see graphic)<br />
• Easy monitoring through integrated undervoltage detection<br />
Order No.<br />
3RK1 901-1MX00<br />
3RK1 901-1MX01<br />
3RX9 801-0AA00<br />
7<br />
<strong>Siemens</strong> LV 1 Short Catalog · 01/2007<br />