<strong>ACG</strong> <strong>HF</strong> <strong>Multi</strong> <strong>ISO</strong> <strong>RFID</strong> <strong>Reader</strong> V1.0<br />

12 Software<br />

By default, data is transmitted at 9600, n, 8, 1, no handshaking. Two protocol modes<br />

are supported. The protocol mode is configured in the reader EEPROM. As factory<br />

default, the ASCII protocol is used.<br />

12.1 ASCII Protocol<br />

This protocol is designed for easy handling. The commands are issued using a<br />

terminal program. Data is transmitted as ASCII hexadecimal that can be displayed on<br />

any terminal program (i.e. HyperTerminal).<br />

Command<br />

Variable length<br />

Data<br />

Variable length<br />

12.2 Binary Protocol<br />

Figure 12-1: ASCII protocol frame<br />

This protocol is designed for industrial applications with synchronization and frame<br />

checking. An addressing byte for party line (master/slave, multi-drop) is also<br />

included.<br />

The protocol usually requires a device driver. Data is transmitted in binary mode. The<br />

reader uses an internal binary watchdog timer to ensure correct framing.<br />

STX Station ID Length Data BCC ETX<br />

1 byte 1 byte 1 byte Variable length 1 byte 1 byte<br />

Figure 12-2: Binary Frame Version 1<br />

The binary frame version 2 is only sent to the host. It is implemented to give<br />

extended information to the host.<br />

Version 2 must be enabled in the Protocol configuration 2 register.<br />

STX Station ID Length Flags Data BCC ETX<br />

1 byte 1 byte 1 byte 1 byte Variable length 1 byte 1 byte<br />

Figure 12-3: Binary Frame Version 2<br />

<strong>ACG</strong> Identification Technologies GmbH 42