<strong>ACG</strong> <strong>HF</strong> <strong>Multi</strong> <strong>ISO</strong> <strong>RFID</strong> <strong>Reader</strong> V1.0<br />
12.3.7 OPMODE, operating mode register (0Eh)<br />
The operation mode register defines which tag types the reader supports. This<br />
register enables fast tag recognition because only defined tag types are requested.<br />
Operation mode register<br />
Bit 7<br />
(MSB)<br />
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0<br />
(LSB)<br />
RFU<br />
ICODE<br />
UID<br />
ICODE<br />
EPC<br />
<strong>ISO</strong> 15693<br />
ICODE<br />
SR176<br />
<strong>ISO</strong><br />
14443B<br />
<strong>ISO</strong><br />
14443A<br />
12.3.8 Single Shot Time-out (0Fh)<br />
Figure 12-13: Operation mode register<br />
The time-out value defines the delay time between two responses of the reader. It<br />
only has effect in continuous read mode. To enable the time-out, the single shot flag<br />
has to be set. See the protocol configuration register above. One time-out slice is<br />
around 100ms. Exact timing depends on the protocol used.<br />
Value 00h indicates no delay time.<br />
Default value is 0Ah (1 second).<br />
12.3.9 Protocol configuration 2 (13h)<br />
The protocol configuration register 2 (PCON2) further specifies the general behavior<br />
of the reader device.<br />
Default value is 00h.<br />
Protocol configuration 2 register<br />
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0<br />
Disable<br />
<strong>ISO</strong><br />
14443 -4<br />
Error<br />
Handling<br />
Enable<br />
<strong>ISO</strong><br />
14443B<br />
Anticollision<br />
Reset<br />
Recovery Time<br />
<strong>Multi</strong>plier<br />
Noisy<br />
Environment<br />
Enable<br />
binary<br />
frame<br />
v2<br />
Figure 12-14: Protocol configuration register<br />
Disable<br />
start-up<br />
message<br />
Disable<br />
multitag<br />
reset<br />
12.3.9.1 Disable multi-tag reset (default 0)<br />
If set, the reader does not reset before the multi-tag list and multi-select command<br />
have been performed.<br />
<strong>ACG</strong> Identification Technologies GmbH 52