Multi Gas Leak Detector <strong>MGLD.3000</strong><br />

Operating instructions<br />

4. Installation and commissioning<br />

Caution!<br />

Follow the safety instructions provided in chapter 2.<br />

4.1. Unpacking device from packing materials<br />

When unpacking the device, examine the device and compare it with the packing list to make sure that all<br />

parts are included and undamaged.<br />

Do not discard the transport packaging. In the event that the materials need to be returned, they will need<br />

to be returned in the original packaging. Only in this way can the returned materials be protected from<br />

damage during transport.<br />

4.2. Installation and commissioning the <strong>MGLD.3000</strong><br />

4.2.1. Stationary operation of the device with docking unit/charging batteries on<br />

the base unit<br />

Caution!<br />

Exercise caution during device assembly and setup to prevent injury to hands and fingers!<br />

Place the docking unit on its feet in the designated location. A level, dry, secure, and stable surface is<br />

required. Make sure the docking unit is placed on a level and stable surface where it cannot slip or wobble.<br />

Connect the included power connection cord to the docking unit power connection.<br />

Caution!<br />

Observe the layout of both devices (front side by front side)! There must be no foreign objects between<br />

the docking unit and the base unit<br />