Multi Gas Leak Detector <strong>MGLD.3000</strong><br />

Operating instructions<br />

5. Care and service<br />

Please follow the general safety instructions in 2.2 of these operating instructions.<br />

Interventions in the device, service or repair works can only be performed by the manufacturer's customer<br />

service department or by authorized professional technicians.<br />

5.1. Cleaning and care<br />

Remove the power plugs from the socket before cleaning.<br />

External cleaning of the <strong>MGLD.3000</strong> and its components may only be performed using a soft,<br />

lightly moistened, non-dripping cloth. Chemical cleaning agents, abrasives, or solvents may not be used.<br />

The contacts between the docking unit and the base unit, between the device and connection line,<br />

probe and connection line, and the interfaces with the rear of the device may only be cleaned with a dry,<br />

dust-free brush.<br />

During longer periods between use, the device and hand probes must be wrapped in their original packaging<br />

materials and placed in storage. Especially with probes, the storage area must be absolutely free of<br />

any impurities and contaminants, and must be specially protected from the influence of chemical substances,<br />

e.g. silicone.<br />

5.2. Service<br />

Before startup, regularly check the electro-pneumatic connection line for kinks, crushing or compression<br />

damage, cracks and other damage and/or impurities. Replace damaged connection lines immediately to<br />

ensure proper leak search results and to protect the device from contamination.<br />

Also regularly check the Teflon tip and the ventilation inlets/outlets on the rear of the device before startup<br />

for dirt buildup and contamination and remove these.<br />

Generally a yearly check of the hand probes by the manufacturer's customer service or by manufacturerauthorized<br />

technicians / an authorized service center is recommended.<br />

We also recommend yearly replacement of all filters by the manufacturer customer service department or<br />

by manufacturer-authorized specialists / an authorized service center.<br />

BAL_MGLD3000_20101001_en.doc 54-54