Programming 27<br />
Command 965 - Set Up Domestic Dialling Format<br />
Command 965 has been added to make the set up of the domestic dialling format a one step<br />
operation. Refer to page 76 for more information on Domestic Reporting Format.<br />
After Installer's Programming Mode has been accessed, enter <strong>com</strong>mand 965 followed by<br />
the # button. This will <strong>au</strong>tomatically set the following locations in bold below. No other<br />
locations will be changed when <strong>com</strong>mand 965 has been issued.<br />
Location Description Setting<br />
LOCATION 49 Handshake Tone 2 (1400 Hz)<br />
LOCATION 50 Transmission Format 11 (Domestic)<br />
LOCATION 052 – 055 Subscriber ID Number 0, 0, 0, 1 (1 Beep)<br />
LOCATION 104 – 111 Zone 1 2, 0, 0, 0, 0, 3, 0, 1 (Delay-1)<br />
LOCATION 112 - 119 Zone 2 1, 0, 0, 0, 0, 3, 0, 1 (Handover)<br />
LOCATION 120 - 127 Zone 3 1, 0, 0, 0, 0, 3, 0, 1 (Handover)<br />
LOCATION 128 - 135 Zone 4 12, 0, 0, 0, 0, 3, 0, 1 (24 Hour)<br />
LOCATION 152 - 153 Bypass Reports 0, 0 (Not Used)<br />
LOCATION 154 - 155 Trouble Reports 0, 0 (Not Used)<br />
LOCATION 156 - 159 Codepad Duress 0, 0, 0, 0 (Not Used)<br />
LOCATION 160 - 163 Codepad Panic 0, 0, 0, 0 (Not Used)<br />
LOCATION 164 - 167 Access Denied 0, 0, 0, 0 (Not Used)<br />
LOCATION 168 - 171 AC Fail 0, 0, 0, 0 (Not Used)<br />
LOCATION 172 - 175 Low Battery 0, 0, 0, 0 (Not Used)<br />
LOCATION 176 - 179 Sensor Watch 0, 0, 0, 0 (Not Used)<br />
LOCATION 180 - 181 Open/Close Reports 0, 0 (Not Used)<br />
LOCATION 182 – 185 Test Report Time 0, 0, 0, 9 (Not Used)<br />
Table 5: Command 965 Def<strong>au</strong>lts<br />
As you can see from the table above, all reporting other than zone alarms have been disabled.<br />
The handshake tone has been set for 1400 Hz tone acknowledgment and the Subscriber ID<br />
Number has been set for one identification beep. The zone reporting has been set so that any<br />
zone that triggers an alarm condition will only report when the alarm occurs, the zone restore<br />
report will not report as there is no separate indications for zone alarm reports and zone alarm<br />
restore reports.<br />
Electronics Design and Manufacturing Pty Limited<br />
ISSUE123.DOC