Programming 29<br />

Command 999 - Display Software Version Number<br />

This <strong>com</strong>mand will display the control panel's software version number. This <strong>com</strong>mand can<br />

only be used with the hand held programmer.<br />

Once access to Installer’s Programming Mode has been gained, enter <strong>com</strong>mand 999<br />

followed by the # button to display the control panel's software version number. Two beeps<br />

will be heard. Press the # button to exit this <strong>com</strong>mand and return to the Installer’s<br />

Programming Mode.<br />

Disable Factory Def<strong>au</strong>lt<br />

LOCATION 900 0<br />

The system has a feature that prevents the control panel from being manually def<strong>au</strong>lted via the<br />

def<strong>au</strong>lt button or by using a programming key unless the Installer’s Code is known.<br />

Any number between 0-14 programmed into this location will allow def<strong>au</strong>lting of the control<br />

panel. If 15 has been programmed into this location, def<strong>au</strong>lting of the control panel will not<br />

operate and the Installer Code MUST be used for further programming of the control panel.<br />

If the Installer Code is not known, the control panel will need to be returned to your EDM<br />

Distributor for exchange. A nominal fee applies for this service.<br />

Electronics Design and Manufacturing Pty Limited does not re<strong>com</strong>mend the use of this<br />

feature.<br />

If the option to prevent def<strong>au</strong>lting of the control panel is required, a special programming<br />

procedure has been introduced to eliminate any possibility of accidentally setting this option.<br />

The def<strong>au</strong>lt button on the PCB must be held down while programming this location.<br />

How To Prevent <strong>Manual</strong> Def<strong>au</strong>lting Of The Control Panel<br />

1. Disarm the system.<br />

2. Access Installer's Programming Mode.<br />

3. Go to "LOCATION 900".<br />

4. Hold down the def<strong>au</strong>lt button.<br />

5. Program a 15 into "LOCATION 900".<br />

6. Release the def<strong>au</strong>lt button.<br />

7. Exit Installer's Programming Mode.<br />

Electronics Design and Manufacturing Pty Limited<br />

ISSUE123.DOC