Programming 29<br />
Command 999 - Display Software Version Number<br />
This <strong>com</strong>mand will display the control panel's software version number. This <strong>com</strong>mand can<br />
only be used with the hand held programmer.<br />
Once access to Installer’s Programming Mode has been gained, enter <strong>com</strong>mand 999<br />
followed by the # button to display the control panel's software version number. Two beeps<br />
will be heard. Press the # button to exit this <strong>com</strong>mand and return to the Installer’s<br />
Programming Mode.<br />
Disable Factory Def<strong>au</strong>lt<br />
LOCATION 900 0<br />
The system has a feature that prevents the control panel from being manually def<strong>au</strong>lted via the<br />
def<strong>au</strong>lt button or by using a programming key unless the Installer’s Code is known.<br />
Any number between 0-14 programmed into this location will allow def<strong>au</strong>lting of the control<br />
panel. If 15 has been programmed into this location, def<strong>au</strong>lting of the control panel will not<br />
operate and the Installer Code MUST be used for further programming of the control panel.<br />
If the Installer Code is not known, the control panel will need to be returned to your EDM<br />
Distributor for exchange. A nominal fee applies for this service.<br />
Electronics Design and Manufacturing Pty Limited does not re<strong>com</strong>mend the use of this<br />
feature.<br />
If the option to prevent def<strong>au</strong>lting of the control panel is required, a special programming<br />
procedure has been introduced to eliminate any possibility of accidentally setting this option.<br />
The def<strong>au</strong>lt button on the PCB must be held down while programming this location.<br />
How To Prevent <strong>Manual</strong> Def<strong>au</strong>lting Of The Control Panel<br />
1. Disarm the system.<br />
2. Access Installer's Programming Mode.<br />
3. Go to "LOCATION 900".<br />
4. Hold down the def<strong>au</strong>lt button.<br />
5. Program a 15 into "LOCATION 900".<br />
6. Release the def<strong>au</strong>lt button.<br />
7. Exit Installer's Programming Mode.<br />
Electronics Design and Manufacturing Pty Limited<br />
ISSUE123.DOC