REMOTE LEVEL CONTROL<br />
{<br />
15<br />
25K Linear Potentiometer<br />
All PLC4.1 Controllers will accept this option for remote control of over all (master) volume control. The potentiometer is<br />
typically installed in a single-gang electrical box with a blank cover panel drilled to accept the control. Simple 3-wire<br />
22ga, or equivalent, interconnection. Wiring is as follows:<br />
Rear<br />
of Pot<br />
PLC4.1 <strong>PowerLinx</strong> Controller<br />
+ Voltage<br />
Master Return<br />
Ground<br />
+ 10V<br />
Master Return<br />
Ground<br />
25K Linear Potentiometer (For PLC4.1 w/factory-installed VCA card option)<br />
Individual <strong>channel</strong> (1, 2, 3, 4 and/or SUB) remote volume control is possible with the factory-option VCA card. (See your<br />
<strong>Tannoy</strong> dealer). One or more potentiometers may control any PLC4.1 output(s) in any combination. This is achieved by<br />
wiring the Master Return connection from the potentiometer(s) to the VCA RETURNS connector (one or more pins) for<br />
the <strong>channel</strong>(s) you wish to control.<br />
EXAMPLE: Channels 1 and 2 are feeding a stereo signal to zone #1 you wish to control. Channel 3 is feeding a mono<br />
signal to zone #2 you wish to control separately. Wire the Master Return connection from zone #1's potentiometer to<br />
VCA RETURN 1 and 2 connector pins. Wire the Master Return connection from zone #2's potentiometer to the<br />
VCA RETURN 3 connector pin. The + 10V and GROUND connections are common to all used potentiometers.<br />
ZONE #1<br />
ZONE #2<br />
PLC4.1 <strong>PowerLinx</strong> Controller<br />
Rear<br />
of Pot<br />
Rear<br />
of Pot<br />
+10V MR<br />
Channels<br />
1 2 3 4 Sub<br />
To +10V<br />
To Channel 3<br />
To Ground<br />
To Channels 1 & 2