Product<br />

PC PRO T8<br />

for brilliant system efficiency<br />

The successful PC PRO T8 ballasts with new “ ” <strong>technology</strong> from <strong>Tridonic</strong>Atco now have<br />

improved properties. Users get added value from system efficiency and lamp management<br />

that are better than ever before.<br />

Always room for improvement<br />

Superb lamp management has always been a characteristic feature<br />

PC PRO T8 electronic ballasts. The tried and tested ASIC guarantee<br />

high levels of lighting comfort and quality. But there is nothing in this<br />

world that cannot be improved so <strong>Tridonic</strong>Atco is once again setting<br />

a milestone in the use of digital control with the introduction of “ ”<br />

<strong>technology</strong>.<br />

A high level of integration and a wealth of further innovative functions<br />

are the impressive results – and with above-average system efficiency.<br />

The PC PRO T8 ballasts – in their one and two-lamp versions –<br />

operate T8 fluorescent lamps with wattages from 18 W to 58 W not<br />

only in accordance with the manufacturer’s specifications but with<br />

innovative added value.<br />

Minimal power loss<br />

Als Now more than ever before energy efficiency is the crucial factor<br />

for many applications. This aspect has been improved in the<br />

PC PRO T8 ballasts as a result of reducing the power loss through<br />

improved thermal management. This positive effect comes directly<br />

from the use of <strong>technology</strong>. Less heat is produced and therefore<br />

the thermal load on the ECG is lower, which increases the reliability<br />

of the device.<br />

The new PC PRO T8 generation has a greater thermal safety margin<br />

(up to 135 %) with respect to the limit temperature at the smoothing<br />

capacitor. As the operating temperature effectively determines the life<br />

of the device a reduction in the constant load of 10 K at the capacitor<br />

translates into a doubling of life – just a reduction of 1 K leads to<br />

a considerable improvement in reliability.<br />

Added value guaranteed<br />

PC PRO T8<br />

ballasts are designed for universal application.<br />

A lifetime of 50,000 hours at an ambient temperature of up to +60 °C<br />

brings long-term benefits.<br />

Plus points all round<br />

As less heat has to be removed, PC PRO T8<br />

Technical data<br />

• Gentle hot restart<br />

• Automatic restart on relamping<br />

• Constant luminous flux even if the mains voltage fluctuates<br />

• Maximum protection for the lamp thanks to<br />

intelligent voltage monitoring (overvoltage/undervoltage)<br />

• Automatic shutdown if the lamp is faulty<br />

• Rapid wiring with insulation piercing terminals<br />

• DC operation possible (emergency lighting)<br />

• Temperature range –25 °C to +60 °C<br />

• Protection classes I and II<br />

• RI suppressed up to 1 GHz (EN 50015 and EN 55022)<br />

• ENEC and VDE EMC tested, CE symbol<br />

provides the ideal<br />

basis for creative lighting design; in other words optimum thermal<br />

management for delicate products.<br />

Existing PC PRO T8 ballasts can be easily replaced with innovative<br />

generation ballasts because the casing dimensions, attachment<br />

points and <strong>connection</strong> positions on both the power supply side and<br />

the lamp side are identical.<br />