CHAPTER 3<br />

QC AND QA LABORATORIES<br />

3.1 General. All laboratories involved in the design, design verification, quality control,<br />

and quality assurance testing of asphalt mixtures and component materials must be<br />

fully equipped to perform the required tests. All such equipment must meet the<br />

requirements of MDOT’s specified test methods.<br />

3.2 QC Laboratory. Post an organization chart, including names, telephone numbers<br />

and current certification (CAT-I, CAT-II and CMDT), of all personnel responsible<br />

for the quality control program on the project. Post the chart in a readily visible<br />

location.<br />

Post all required quality control charts in a readily visible location, and maintain in<br />

an up-to-date status. Charts may be maintained on a computer. However, updated<br />

computer charts shall be printed and displayed at a minimum of once each<br />

production day.<br />

The laboratory shall be setup and calibrated prior to production. Calibration shall be<br />

according to the procedures and frequencies given in AASHTO R 18. Inspect and<br />

calibrate the laboratory equipment as follows:<br />

Check calibration of Gyratory compactor according to the requirements in the<br />

manufacturer’s manual (at a minimum, verify the angle of gyration and the load<br />

on the specimen during compaction).<br />

Check balances for accuracy, precision and readability in accordance with<br />

AASHTO M 231.<br />

Check the water baths used for specific gravity testing for constant water level,<br />

temperature, and make sure the specimen basket does not touch the walls of the<br />

tank each time testing is performed. Make sure a non-corrosive metal wire or a<br />

non-absorptive cord is used to hang the basket from the bottom of the balance.<br />

Check calibration of maximum specific gravity flask and fine aggregate<br />

angularity cylinder.<br />

Check vacuum pumps to confirm that the required pressure is being applied to<br />

the flask or pycnometer.<br />

Check accuracy of all thermometers.<br />

Check temperature of ovens and water baths.<br />

Rev. February 5, 2007 12