07.11.2014 Views

2 0 1 2 P R O D U C T C A T A L O G U E - Klima-Therm

2 0 1 2 P R O D U C T C A T A L O G U E - Klima-Therm

2 0 1 2 P R O D U C T C A T A L O G U E - Klima-Therm

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Floor<br />

Simple & Thin design<br />

harmonizes with the interior<br />

Filter features<br />

Long-life* Ion Deodorization Filter<br />

The filter deodorizes by powerfully decomposing absorbed<br />

odors using the oxidizing and reducing effects of ions<br />

generated by the ultra-fine-particle ceramic.<br />

(*The filter can be used for approx. 3 years if it is washed under water to<br />

restore its surface action when it is dirty.)<br />

Apple-catechin Filter<br />

Flexible piping connection<br />

6 direction of drain & piping<br />

Back view<br />

1 6<br />

2<br />

3 Drain hose 4<br />

Piping<br />

5<br />

CLASS<br />

A<br />

ALL<br />

DC<br />

AGYF09LA AGYF12LA AGYF14LA<br />

Flexible & easy installation<br />

Beneath<br />

standard window<br />

CLASS<br />

A<br />

ALL<br />

DC<br />

Standard concave<br />

portion<br />

Min.940<br />

CLASS<br />

A<br />

Wall<br />

ALL<br />

DC<br />

Half concealed<br />

(Optional parts necessary)<br />

For AGYF09/12LA<br />

For AGYF14LA<br />

2-Fan & Wide airflow<br />

Cooling<br />

Prevents cold air<br />

from falling<br />

Apple-catechin Filter<br />

Fine dust, invisible mold spores, and harmful microorganisms<br />

are absorbed onto the filter by static electricity, and further<br />

growth is inhibited and deactivated by the polyphenol<br />

extracted from apples.<br />

10°C HEAT Operation<br />

Using different filters at both sides<br />

Ion Deodorization<br />

Filter<br />

The room temperature can be set to go no lower than 10°C, thus ensuring that<br />

the room does not get too cold when not occupied<br />

Caution<br />

•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start.<br />

Operation starts and maintains the room temperature at 10°C when the temperature<br />

drops below 10°C.<br />

•When “10°C HEAT” operation stops, the room set temperature quickly returns to the<br />

preset temperature.<br />

Low ambient operation<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

Cooling<br />

43°C<br />

-10°C<br />

Quiet operation<br />

Industry leading noise levels<br />

Heating<br />

24°C<br />

-15°C<br />

600<br />

740<br />

700<br />

200<br />

(unit:mm)<br />

Min.<br />

700<br />

(unit:mm)<br />

Max. 150<br />

(unit:mm)<br />

Min.<br />

590<br />

Min. 730<br />

Max.<br />

80<br />

(unit:mm)<br />

at operation<br />

start<br />

Heating<br />

at operation<br />

start<br />

at stable<br />

operation<br />

Prevents cold<br />

draft from<br />

window<br />

at stable<br />

operation<br />

Window<br />

20°C<br />

10°C<br />

“10°C HEAT”<br />

Button ON<br />

Easy maintenance<br />

Washable panel removable<br />

Indoor unit<br />

operation START<br />

Removable panel<br />

“10°C HEAT”<br />

Button ON<br />

Fan speed<br />

Quiet<br />

Optional parts<br />

Low level<br />

22dB(A)<br />

Wired Remote Controller: UTY-RNNYM<br />

Half Concealed Kit: UTR-STA<br />

External Connect Kit: UTY-XWZX<br />

Specifications Dimensions Models: AGYF09LA / AGYF12LA / AGYF14LA<br />

(Unit : mm)<br />

Model No.<br />

Indoor unit<br />

Outdoor unit<br />

AGYF09LA<br />

AOYV09LA<br />

AGYF12LA<br />

AOYV12LA<br />

AGYF14LA<br />

AOYV14LA<br />

200<br />

Power Source<br />

Capacity<br />

Input Power<br />

EER - Energy Class<br />

COP - Energy Class<br />

Running Current<br />

Moisture Removal<br />

Noise (Indoor)<br />

Noise (Outdoor)<br />

Airflow Rate (High)<br />

Cooling<br />

Heating<br />

Cooling/Heating<br />

Cooling<br />

Heating<br />

Cooling/Heating<br />

Cooling H/M/L/Q<br />

Cooling<br />

Indoor/Outdoor<br />

V/Ø/Hz<br />

kW<br />

kW<br />

W/W<br />

A<br />

I/h<br />

dB(A)<br />

m 3 /h<br />

230/1/50<br />

2.60(0.9~3.5)<br />

3.50(0.9~5.5)<br />

0.53/0.79<br />

4.91-A<br />

4.43-A<br />

2.6/3.8<br />

1.3<br />

40/35/29/22<br />

47<br />

570/1680<br />

230/1/50<br />

3.50(0.9~4.0)<br />

4.50(0.9~6.6)<br />

0.94/1.19<br />

3.72-A<br />

3.78-A<br />

4.4/5.5<br />

1.8<br />

40/35/29/22<br />

48<br />

570/1680<br />

230/1/50<br />

4.20(0.9~5.0)<br />

5.20(0.9~8.0)<br />

1.14/1.44<br />

3.68-A<br />

3.61-A<br />

5.2/6.4<br />

2.1<br />

44/38/31/22<br />

50<br />

650/1910<br />

600<br />

Net Dimension<br />

H x W x D<br />

Piping Connections (Small / Large)<br />

Drain Pipe Diameter (I.D./O.D.)<br />

Max Pipe Length (Pre-Charge)<br />

Height Difference<br />

Operation<br />

Range<br />

Refrigerant<br />

Indoor<br />

Outdoor<br />

Cooling<br />

Heating<br />

mm<br />

kg(lbs)<br />

mm<br />

kg(lbs)<br />

mm<br />

mm<br />

m<br />

°CDB<br />

600x740x200<br />

14(31)<br />

540x790x290<br />

36(79)<br />

6.35/9.52<br />

13.8/15.8 to 16.7<br />

20(15)<br />

15<br />

-10~43<br />

-15~24<br />

R410A<br />

600x740x200<br />

14(31)<br />

540x790x290<br />

36(79)<br />

6.35/9.52<br />

13.8/15.8 to16.7<br />

20(15)<br />

15<br />

-10~43<br />

-15~24<br />

R410A<br />

600x740x200<br />

14(31)<br />

578x790x300<br />

40(88)<br />

6.35/12.7<br />

13.8/15.8 to 16.7<br />

20(15)<br />

15<br />

-10~43<br />

-15~24<br />

R410A<br />

740<br />

Front view<br />

Side view<br />

038<br />

039

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!