Maximum comfort from<br />

inbuilt flexibility<br />

Design Versatility<br />

Long piping system design<br />

High capacity connection<br />

•Equivalent pipe length: 120m maximum.<br />

•Total pipe length: 200m maximum.<br />

Height difference<br />

15m max.<br />

One outdoor unit can control<br />

up to 16 indoor units (28kW) of<br />

different types and capacities.<br />

Connectable capacity of indoor<br />

units for one outdoor unit<br />

50 to 130%<br />

Heat recovery<br />

AO90MPCMF<br />

Actual pipe length<br />

100m max.<br />

MAX Connectable indoor unit<br />

16<br />

High Efficiency<br />

Height difference<br />

50m max.<br />

Wide operating range<br />

Operating system<br />

Cooling and heating can be performed simultaneously within<br />

the same refrigerant circuit.<br />

Energy savings are made by transferring heat between the<br />

indoor units when in heat recovery operation.<br />

Cooling EER<br />

2.98 *<br />

Heating COP<br />

3.15 *<br />

*EER/COP values are base on<br />

our own testing method.<br />

Power accumulation technology<br />

Flow rate to the indoor unit(s) is controlled through the use of<br />

3 differently rated compressors operating in a sequential step<br />

arrangement. While power accumulation technology controls<br />

the circulating load of the refrigerant flow between those steps.<br />

Diagram<br />

*When outdoor unit is located above indoor unit. When outdoor unit is located<br />

below the indoor unit the height difference is 40m maximum.<br />

Outdoor unit operates over<br />

an outdoor temperature<br />

range of -5°C to 52°C for<br />

cooling and -15°C to 21°C<br />

for heating.<br />

Cooling<br />

52°C<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10 -5°C<br />

Heating<br />

21°C<br />

-15°C<br />

Smooth operation delivering<br />

high efficiencies<br />

The configuration of 3 constant<br />

speed compressors with<br />

differing capacities and power<br />

accumulation technology ensure<br />

smooth step changes and highly<br />

efficient operation.<br />

Comfortable Operation<br />

Heat recovery operation<br />

High<br />

Required<br />

capacity<br />

low<br />

1 2<br />

1 2 3 3 3 3<br />

High<br />

Operating capacity<br />

1<br />

2<br />

Flow of refrigerant<br />

Comp.1<br />

Comp.2<br />

Comp.3<br />

Power accumulation<br />

technology<br />

High Reliability<br />

Recovery operation<br />

Outdoor Unit: In the event of<br />

compressor failure an alarm is<br />

automatically triggered and the<br />

remaining compressor(s) will<br />

continue to operate, thereby<br />

ensuring continuous operation when<br />

possible.<br />

Comp.1<br />

Comp.2<br />

Comp.3<br />

Indoor Unit: Each indoor unit operates independently from the<br />

others and is, therefore, not affected by a failure within any part<br />

of the network.<br />

Improved Comfort<br />

Quiet operation<br />

Operational noise has been reduced yet further through the<br />

application of a new dual casing bell-mouth and large fan.<br />

When set to silent operation, noise levels can be reduced by<br />

5-6dB(A) compared to normal operation.<br />

Normal operation mode<br />

55dB(A)<br />

Silent operation mode<br />

50dB(A)<br />

(380V)<br />

Heat recovery operation is a cooling/heating free operation system, cooling and heating can be<br />

performed simultaneously in the same refrigerant system according to user needs.<br />

At the moment, the Heat Recovery operation is an extremely superior type that provides a still<br />

greater energy saving effect by moving heat between indoor units that are performing the cooling<br />

and heating operations. This is by having the compressors act like a pump.<br />

Oil recovery operation<br />

After a fixed period of time the oil recovery operation<br />

automatically returns accumulated oil found in the refrigerant<br />

circuit and indoor units.<br />

100<br />

101