Easy Installation<br />

Outdoor units specifications<br />

Space saving<br />

Easy wiring<br />

Dimensions<br />

Model: AO90MPCMF<br />

(Unit : mm)<br />

Space saving by setting side<br />

Setting size<br />

by side without space in<br />

5.72<br />

between. (Unit: m2)<br />

Transmission line:<br />

Non-polar 2-conductor transmission<br />

line prevents erroneous wiring.<br />

Transmission line<br />

1000mm(Boltpitch)<br />

850mm<br />

Dimensions<br />

Outdoor unit goes into elevator<br />

Power supply wiring:<br />

Power supply for outdoor and<br />

indoor units is different.<br />

678mm<br />

1,380<br />

800<br />

1,050<br />

•Outdoor unit<br />

3Ø 4W 380 - 415V 50Hz<br />

•Indoor unit:<br />

1Ø 2W 220 - 240V 50Hz<br />

1,300<br />

Installation space<br />

650<br />

(Unit : mm)<br />

1,500<br />

(Unit : mm)<br />

Outdoor unit<br />

Transmission line<br />

Transmission<br />

adaptor<br />

Central<br />

remote controller<br />

PC<br />

controller<br />

1380mm<br />

For individually<br />

10mm or more<br />

For continuous<br />

10mm or more<br />

Indoor unit<br />

FRONT<br />

SIDE<br />

500mm<br />

or more<br />

h<br />

10mm or more<br />

Top air outlet<br />

L1 L2<br />

300mm<br />

or more<br />

h<br />

500mm<br />

or more<br />

10mm<br />

or more<br />

FRONT<br />

SIDE<br />

10mm<br />

or more<br />

300mm<br />

or more<br />

Craning into place<br />

Protective boards<br />

1300mm<br />

650mm<br />

703mm<br />

H(1200mm)<br />

H(1200mm)<br />

10mm<br />

or more<br />

The outdoor unit can be lifted by crane<br />

and set down on the building roof.<br />

Front side<br />

intake port<br />

Back side<br />

intake port<br />

There is no height restriction for the side wall.<br />

The height(H) of front and rear wall should be less than1,200mm.<br />

If the height of wall exceeds 1,200mm by h mm, add h mm to the service<br />

space width for L1 and L2.<br />

H 1,200 : L1 500, L2 300 H 1,200 + h : L1 500 + h, L2 300 + h<br />

Four-direction pipe<br />

Four-direction piping allows a variety of<br />

installation configurations.<br />

Easy installation and pipe direction<br />

setting.<br />

1<br />

Front<br />

2<br />

Bottom<br />

4<br />

Back<br />

3<br />

Right<br />

Specifications<br />

Rating Capacity range<br />

Model name<br />

Maximum Connectable Indoor Unit<br />

Indoor unit connectable capacity Cooling<br />

HP<br />

kW<br />

10<br />

AO90MPCMF<br />

16<br />

14 to 36.4<br />

Easy Maintenance<br />

Operating display<br />

By indicating the operating status and<br />

details of failures on a PCB in the<br />

outdoor unit, better service and quick<br />

and easy maintenance are possible.<br />

Pump down control<br />

Operation display<br />

Pump down can be performed from the outdoor unit using the<br />

switch on the PCB.<br />

Easy replacement<br />

A pull-out plate ensures easy<br />

compressor replacement if necessary.<br />

Power source<br />

Capacity<br />

Input power<br />

EER<br />

COP<br />

Air flow rate<br />

Sound<br />

pressure level<br />

Compressor motor output<br />

Heat exchanger fin<br />

Dimensions<br />

Weight<br />

Refrigerant charge<br />

Connection<br />

pipe diameter<br />

Operation<br />

range<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

High<br />

Normal operation mode<br />

Silent operation mode<br />

Height<br />

Width<br />

Depth<br />

kW<br />

kW<br />

kW<br />

W/W<br />

m 3 /h<br />

dB<br />

(A)<br />

mm<br />

mm<br />

mm<br />

kg<br />

kg<br />

Liquid<br />

mm<br />

Gas<br />

Cooling<br />

˚C<br />

Heating<br />

Note : Specifications are based on the following conditions.<br />

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.<br />

Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.<br />

3 phase, 380 - 415V, 50Hz<br />

28.0<br />

31.5<br />

9.40<br />

10.0<br />

2.98<br />

3.15<br />

9,800<br />

57<br />

51<br />

1.5 / 3.4 / 5.0<br />

Plate fin coil<br />

1,380<br />

1,300<br />

650<br />

305<br />

11.8<br />

ø12.70<br />

Discharge Gas ø19.05 / Suction Gas ø28.58<br />

-5 to 52<br />

-15 to 21<br />

102<br />

103