2 0 1 2 P R O D U C T C A T A L O G U E - Klima-Therm
2 0 1 2 P R O D U C T C A T A L O G U E - Klima-Therm
2 0 1 2 P R O D U C T C A T A L O G U E - Klima-Therm
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
High Reliability<br />
Easy Installation<br />
Life-extending operation<br />
Easily transported<br />
Easy access<br />
Outdoor unit operation rotation<br />
The compressor starting order is rotated so that the running time is shared.<br />
Rotation<br />
Rotation<br />
Rotation<br />
Light weight<br />
Easily craned into<br />
position using<br />
lifting belt hooks<br />
20%<br />
weight reduction<br />
(Than Previous model)<br />
Note:<br />
In the case of 14HP<br />
Can be transported in<br />
a small elevator<br />
By adopting a L-Shape front panel<br />
that can be removed, the work<br />
space for installation and service<br />
has been significantly expanded by<br />
this new design. For multiple<br />
installations, work is performed<br />
easily and efficiently even in a<br />
narrow space.<br />
DC<br />
1<br />
AC<br />
4<br />
DC<br />
2<br />
AC<br />
5<br />
DC<br />
3<br />
DC<br />
1<br />
AC<br />
4<br />
DC<br />
2<br />
AC<br />
5<br />
DC<br />
3<br />
DC<br />
1<br />
AC<br />
4<br />
DC<br />
2<br />
AC<br />
5<br />
DC<br />
3<br />
Expansion of work space<br />
Note: The inverter compressors start in priority.Rotate operation is alternated by the start / stop timing of the compressors<br />
Design of outdoor unit allows for<br />
lifting straps to be used<br />
Backup operation<br />
Transporting by forklift<br />
If one of twocompressors malfunctions,<br />
it will not affect the operation of the remaining outdoor units.<br />
Outdoor Units<br />
If one of compressors fails, backup operation will be<br />
performed by the remaining compressors as emergency.<br />
Indoor unit continuous operation<br />
Each indoor unit is controlled individually on the system<br />
network. This allows all indoor units to continue to operate<br />
unaffected even if an error should occur at any indoor unit’s on<br />
the VRF network system.<br />
Failure<br />
Simple signal line connection<br />
Installation is made easier as the<br />
communications wiring can be connected<br />
continuously to any component.<br />
Up to maximum<br />
length 3,600m<br />
V-II series<br />
Easy piping connection<br />
The need for a oil equalization pipe as required on the<br />
previous model has been removed. The installation costs<br />
have been reduced by employing a simple 2 pipe connection<br />
Adoption of blue fin heat exchanger<br />
Remote monitoring<br />
Corrosion resistant of the heat exchanger has been improved<br />
by the introduction of blue fin treatment to the outdoor unit’s<br />
heat exchanger.<br />
The Web Monitoring system allows you view system operation<br />
at all times over the internet ensuring trouble free operation.<br />
Monitoring Side<br />
Other wiring method<br />
Simple wiring method<br />
Note: In a multiple refrigerant system installation, Automatic addressing sequence cannot be<br />
initiated<br />
Eliminating oil equalization pipe<br />
Blue fin<br />
heat exchanger<br />
Cobalt Blue protection<br />
Standard chromate protection<br />
Aluminium base material<br />
Hydrophilic coating<br />
Internet<br />
or<br />
Public Telephone Line<br />
VRF Network System Side<br />
Outdoor unit<br />
Transmission<br />
line<br />
USB adaptor<br />
(Field supplied)<br />
Automatic address setting<br />
The address of each indoor unit<br />
can be automatically set by<br />
button switch of outdoor unit.<br />
Automatic address<br />
setting is performed<br />
at outdoor unit<br />
Addresses are automatically<br />
distributed from outdoor unit.<br />
Web<br />
Monitoring Tool<br />
3 7 1 0<br />
Indoor unit<br />
The operating VRF network system in the building can be<br />
monitored in real time over the Internet.<br />
Press the pushbutton<br />
switch of outdoor unit.<br />
2 4 5 6<br />
Manual address setting from indoor unit and remote controller is also possible.<br />
120<br />
121