Control Systems Lineup<br />
Comparison table of Controllers<br />
Individual<br />
control<br />
system<br />
Type<br />
Wired<br />
Remote Controller<br />
S<br />
UTB-YUB<br />
VRF<br />
J-II & V-II<br />
UTY-RNKY<br />
Type<br />
Wired<br />
Remote<br />
Controller<br />
Individual control<br />
Simple<br />
Remote<br />
Controller<br />
*1<br />
Simple<br />
Remote<br />
Controller<br />
Wireless<br />
Remote<br />
Controller<br />
Group<br />
Remote<br />
Controller<br />
Central<br />
Remote<br />
Controller<br />
Centralized control<br />
Central<br />
Remote<br />
Controller<br />
Touch<br />
Panel<br />
Controller<br />
System<br />
Controller<br />
(Software)<br />
Simple<br />
Remote Controller<br />
UTB-YPB<br />
UTY-RSKY<br />
Model name<br />
UTB-YUB<br />
UTY-RNKY<br />
UTB-YPB<br />
UTY-RSKY<br />
UTB-YRA<br />
UTY-RHKY<br />
UTB-YVB<br />
UTY-LNHY<br />
UTB-YDB<br />
UTY-DCGY<br />
UTY-CGGY<br />
UTB-YCA<br />
UTY-DTGY UTY-APGX<br />
Simple<br />
Remote Controller<br />
(Without operation mode)<br />
UTB-YRA<br />
UTY-RHKY<br />
Max. controllable remote controller groups<br />
Max. controllable indoor units<br />
1<br />
16<br />
1<br />
16<br />
1<br />
16<br />
1<br />
16<br />
8<br />
96<br />
100<br />
100<br />
400<br />
400<br />
400<br />
400<br />
1600<br />
1600<br />
Wireless<br />
Remote Controller<br />
UTB-YVB<br />
UTY-LNHY<br />
Max. controllable groups<br />
On / Off<br />
Operating mode setting<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
16<br />
64<br />
400<br />
1600<br />
Centralized<br />
control<br />
system<br />
IR Receiver Unit<br />
IR Receiver Kit<br />
Group<br />
Remote Controller<br />
Central<br />
Remote Controller<br />
UTB-YWA<br />
-<br />
UTB-YDB<br />
-<br />
UTB-YWC<br />
UTY-LRHYB1<br />
UTY-CGGY<br />
UTY-DCGY<br />
Air conditioning control function<br />
Fan speed setting<br />
Room temp. setting<br />
Room temp. set point limitation<br />
Test operation<br />
Up/down air direction flap setting<br />
Right/left air direction flap setting<br />
Group setting<br />
RC prohibition<br />
Anti freeze setting<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Economy mode setting<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Central<br />
Remote Controller<br />
UTB-YCA<br />
-<br />
Failure<br />
Defrosting<br />
-<br />
-<br />
-<br />
-<br />
Touch panel<br />
Controller<br />
-<br />
UTY-DTGY<br />
Display<br />
Current time<br />
Day of week<br />
R.C. prohibition<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
System Controller<br />
UTY-APGX<br />
UTY-APGX<br />
UTY-PEGX<br />
Cooling/heating priority<br />
Address display<br />
-<br />
-<br />
Adaptor &<br />
Convertor<br />
Network Convertor<br />
UTR-YRDA<br />
UTY-VGGXZ1<br />
Schedule timer<br />
Period<br />
On/off per day<br />
Week<br />
4<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Week<br />
4<br />
Week<br />
20<br />
Week<br />
4<br />
Year<br />
20<br />
Year<br />
72<br />
On/off per week<br />
28<br />
-<br />
-<br />
-<br />
28<br />
140<br />
28<br />
140<br />
504<br />
Network Convertor<br />
for LONWORKS®<br />
UTR-YLLA<br />
UTY-VLGX<br />
Timer<br />
On/off timer<br />
Sleep timer<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
BACnet® Gateway<br />
UTY-ABGX<br />
UTY-ABGX<br />
Program timer<br />
Day off<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Min. unit of timer setting(Minutes)<br />
30<br />
-<br />
-<br />
5<br />
10<br />
10<br />
10<br />
10<br />
10<br />
Signal Amplifier<br />
UTY-VSGX<br />
UTY-VSGX<br />
Status monitoring system<br />
Electricity charge calculation<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Service &<br />
Maintenance<br />
External<br />
Switch Controller<br />
Service Tool<br />
UTR-YESA<br />
UTY-TEKX<br />
UTY-ASGX<br />
UTY-TEKX<br />
UTY-ASGX<br />
Control<br />
Error history<br />
Emergency stop<br />
Control via internet<br />
E-mail notification for malfunction<br />
*1 "Operation mode" setting is not available for this model.<br />
*2 This function is available only through external input. control.<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
*2<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
*2<br />
-<br />
Web Monitoring Tool<br />
UTY-AMGX<br />
UTY-AMGX<br />
134<br />
135