Control Systems for & series<br />

System diagram<br />

The V-II system supports every users needs by offering a variety of Control systems,<br />

including individual control, central control and building management control options.<br />

Wiring system<br />

•Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring.<br />

•Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers).<br />

Max. transmission<br />

line length<br />

3,600m<br />

Building<br />

Management<br />

Air Conditioning<br />

Central Control<br />

System Controller (Software)<br />

UTY-APGX<br />

Internet or Public<br />

Telephone Line<br />

USB<br />

Adaptor*2<br />

(Field supplied)<br />

Air Conditioning<br />

Individual Control<br />

Wired Remote Controller<br />

UTY-RNKY<br />

Simple Remote Controller<br />

UTY-RSKY<br />

Outdoor unit<br />

Indoor unit<br />

System<br />

System Controller UTY-APGX<br />

•Maximum 1,600 indoor units can be controlled.<br />

•Air conditioning control<br />

•Operation monitoring<br />

•Status monitoring system<br />

•Electricity charge calculation<br />

Refrigerant system 1 Refrigerant system 2<br />

Building Management System<br />

BACnet®<br />

BACnet® Gateway<br />

Network Convertor<br />

NW1<br />

NW2<br />

NW3<br />

NW4<br />

USB adaptor<br />

Touch Panel Controller<br />

One Touch Panel Controller cancontrol<br />

up to 400 groups / 400 indoor units.<br />

Central Remote Controller<br />

Maximum 100 indoor units can be controlled.<br />

Internet<br />

or<br />

Public Telephone Line<br />

Group Remote Controller<br />

Maximum 8 remote controller groups can be controlled<br />

(Remote / Monitoring side)<br />

Touch Panel Controller<br />

UTY-DTGY<br />

Remote/Monitoring side<br />

Signal Amplifier<br />

UTY-VSGX<br />

BACnet®<br />

USB<br />

adaptor<br />

Remote controller line<br />

Maximum 16 units<br />

can be controlled<br />

IR Receiver Kit<br />

Cassette type indoor unit can be<br />

controlled with Wireless Remote Controller<br />

Central Remote Controller<br />

UTY-DCGY<br />

Simple Remote Controller<br />

UTY-RHKY<br />

Without<br />

operation mode<br />

IR Receiver Unit<br />

UTB-YWB<br />

UTB-YWC<br />

BACnet® Operator<br />

Workstation (B-OWS)<br />

Network<br />

Convertor<br />

System without remote controller<br />

Together with Touch Panel Controller, it is<br />

possible to build non remote controller system.<br />

IR Receiver Unit<br />

Duct type indoor unit<br />

can be controlled with<br />

Wireless Remote Controller.<br />

General-purpose<br />

Building Control Computer<br />

Connectable to<br />

various sized BMS/BAS*1<br />

Group Remote Controller<br />

UTY-CGGY<br />

BACnet ® Gateway (Software)<br />

UTY-ABGX<br />

Network<br />

Convertor<br />

UTY-VGGXZ1<br />

USB<br />

Adaptor*2<br />

(Field supplied)<br />

Wireless Remote Controller<br />

UTY-LNHY<br />

IR Receiver Kit<br />

UTY-LRHYB1<br />

LONWORKS®<br />

Transmission line<br />

line is non-polar 2-conductor.<br />

Web Monitoring Tool<br />

Trouble free operation at all times<br />

by remote monitoring system.<br />

LONWORKS®<br />

Network<br />

Web Monitoring Tool<br />

Signal Amplifier<br />

USB<br />

adaptor<br />

2 Remote Controllers<br />

Indoor unit can be controlled<br />

from both remote controllers.<br />

Network Convertor<br />

Card key<br />

External Switch Controller<br />

Indoor units can be controlled by<br />

combining with Card-key switch<br />

such as hotel room.<br />

Network Convertor<br />

or<br />

Internet or<br />

Public Telephone Line<br />

Network Convertor<br />

(BMS / LONWORKS®)<br />

UTY-VLGX<br />

Web Monitoring<br />

Tool (Software)<br />

UTY-AMGX<br />

USB<br />

Adaptor*2<br />

Card-key<br />

(Field supplied)<br />

USB<br />

Adaptor*2<br />

External<br />

Switch Controller<br />

UTY-TEKX<br />

Service Tool (Software)<br />

UTY-ASGX<br />

For single split<br />

Network<br />

Convertor<br />

UTY-VGGX<br />

(Monitoring side)<br />

Internet<br />

or<br />

Public Telephone Line<br />

(VRF system side)<br />

Service Tool<br />

USB adaptor<br />

Outdoor<br />

unit<br />

Big multi system<br />

Service Tool<br />

Extensive monitoring and analysis functions for<br />

installation and maintenance.<br />

Touch Panel<br />

Controller<br />

Simple<br />

Remote Controller<br />

IR Receiver<br />

unit<br />

Single system<br />

Transmission line<br />

Module link<br />

(VRF system side)<br />

(Field supplied)<br />

(Field supplied)<br />

(Monitoring side)<br />

Indoor unit<br />

(Cassette)<br />

Central<br />

Remote Controller<br />

Simple<br />

Remote Controller<br />

Remote Controller line<br />

USB cable<br />

(Monitoring side)<br />

*1. BMS/BAS: Building Management System / Building Automation System<br />

*2. USB Adaptor is U10 USB Network Interface of Echelon ® Corporation.<br />

The devices above cannot be connected to the S series.<br />

(Except System Controller & BACnet® Gateway)<br />

Transmission line (VRF Network)<br />

Module link<br />

Remote controller line<br />

USB cable<br />

LONWORKS® Network<br />

Ethernet<br />

Signal line(Single split system)<br />

Group Remote Controller line<br />

(Monitoring side)<br />

Combination of<br />

individual remote controller<br />

Wired, Simple and Wireless Remote Controllers<br />

can be used jointly.<br />

Indoor unit<br />

(Duct)<br />

System<br />

Controller<br />

Group<br />

Remote Controller<br />

Wireless<br />

Remote Controller<br />

Wireless<br />

Remote Controller<br />

External Switch<br />

Controller<br />

LONWORKS® Network<br />

Ethernet<br />

Signal line (single system)<br />

Group Remote Controller line<br />

138<br />

139