More Design Flexibility<br />

Easy Installation<br />

Long Piping Length<br />

Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length<br />

of 180 m. This opens up new possibilities in system design.<br />

Actual piping length<br />

120m max.<br />

Total pipe length<br />

180m max.<br />

Height difference between<br />

outdoor and indoor units<br />

30m max.<br />

Easier Installation<br />

Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new<br />

possibilities in system design.<br />

Easy piping connection : Improvement of the reliability by decreasing<br />

the flare connection.<br />

J-II series<br />

Power supply<br />

(Outdoor )<br />

Flare connection<br />

Terminal box<br />

Power supply cable<br />

Previous model<br />

EV kit<br />

Power supply<br />

(Indoor )<br />

Flare<br />

connection<br />

Flexible installation of outdoor unit :<br />

Corresponds to the outdoor unit concentration<br />

installation.<br />

Reduced installation<br />

intervals by<br />

front access<br />

Easy wiring connection<br />

• Decreasing wiring mistakes by using non-polar 2 wires. (Remote<br />

controller cable is 3 wires)<br />

• Improvement of wiring installation by common with V-II power supply<br />

method.<br />

Flexible installation by<br />

4 way pipe direction<br />

Piping length from first<br />

separation tube to the<br />

farthest indoor unit<br />

40m max.<br />

Height difference between<br />

indoor and indoor units<br />

15m max.<br />

Convenient Commissioning Support<br />

Automatic address setting function : The address of each indoor unit<br />

can be automatically set by button switch of outdoor unit.<br />

Connection check function : Possible to<br />

confirm whether wiring connection and address<br />

setting are correct by check run function for a<br />

short time.<br />

High Capacity Connection<br />

Indoor unit<br />

12 types, 52 models<br />

Number of connectable indoor unit<br />

4 HP<br />

2 to 6<br />

units<br />

5 HP<br />

2 to 8<br />

units<br />

6 HP<br />

2 to 9<br />

units<br />

Connectable indoor unit<br />

capacity range<br />

130 % max.<br />

Wide operating range<br />

Installation in extreme temperature conditions is possible<br />

due to an increase in operational range.<br />

Cooling : -5°C~46°C<br />

Heating : -20°C~21°C<br />

(°C)<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

-20<br />

Cooling<br />

46°C<br />

-5°C<br />

Heating<br />

21°C<br />

-20°C<br />

-20°C area<br />

Operation possible<br />

in heating.<br />

3 7 1 0 2 4 5 6<br />

Easy to connect<br />

with V-II communication system<br />

It is possible to connect directly with the transmission<br />

cable of the V-II system without convertor.<br />

Press the push button<br />

of outdoor unit.<br />

J-II system<br />

Connects without a converter<br />

• Display connected indoor unit numbers<br />

• Duplicately set address number of<br />

indoor unit can be displayed<br />

V-II system<br />

112<br />

113