More Design Flexibility<br />
Easy Installation<br />
Long Piping Length<br />
Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length<br />
of 180 m. This opens up new possibilities in system design.<br />
Actual piping length<br />
120m max.<br />
Total pipe length<br />
180m max.<br />
Height difference between<br />
outdoor and indoor units<br />
30m max.<br />
Easier Installation<br />
Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new<br />
possibilities in system design.<br />
Easy piping connection : Improvement of the reliability by decreasing<br />
the flare connection.<br />
J-II series<br />
Power supply<br />
(Outdoor )<br />
Flare connection<br />
Terminal box<br />
Power supply cable<br />
Previous model<br />
EV kit<br />
Power supply<br />
(Indoor )<br />
Flare<br />
connection<br />
Flexible installation of outdoor unit :<br />
Corresponds to the outdoor unit concentration<br />
installation.<br />
Reduced installation<br />
intervals by<br />
front access<br />
Easy wiring connection<br />
• Decreasing wiring mistakes by using non-polar 2 wires. (Remote<br />
controller cable is 3 wires)<br />
• Improvement of wiring installation by common with V-II power supply<br />
method.<br />
Flexible installation by<br />
4 way pipe direction<br />
Piping length from first<br />
separation tube to the<br />
farthest indoor unit<br />
40m max.<br />
Height difference between<br />
indoor and indoor units<br />
15m max.<br />
Convenient Commissioning Support<br />
Automatic address setting function : The address of each indoor unit<br />
can be automatically set by button switch of outdoor unit.<br />
Connection check function : Possible to<br />
confirm whether wiring connection and address<br />
setting are correct by check run function for a<br />
short time.<br />
High Capacity Connection<br />
Indoor unit<br />
12 types, 52 models<br />
Number of connectable indoor unit<br />
4 HP<br />
2 to 6<br />
units<br />
5 HP<br />
2 to 8<br />
units<br />
6 HP<br />
2 to 9<br />
units<br />
Connectable indoor unit<br />
capacity range<br />
130 % max.<br />
Wide operating range<br />
Installation in extreme temperature conditions is possible<br />
due to an increase in operational range.<br />
Cooling : -5°C~46°C<br />
Heating : -20°C~21°C<br />
(°C)<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
-10<br />
-20<br />
Cooling<br />
46°C<br />
-5°C<br />
Heating<br />
21°C<br />
-20°C<br />
-20°C area<br />
Operation possible<br />
in heating.<br />
3 7 1 0 2 4 5 6<br />
Easy to connect<br />
with V-II communication system<br />
It is possible to connect directly with the transmission<br />
cable of the V-II system without convertor.<br />
Press the push button<br />
of outdoor unit.<br />
J-II system<br />
Connects without a converter<br />
• Display connected indoor unit numbers<br />
• Duplicately set address number of<br />
indoor unit can be displayed<br />
V-II system<br />
112<br />
113