Easy Maintenance<br />

Outdoor units specifications<br />

Design for Easy Maintenance<br />

Dimensions<br />

166<br />

Model: AJYA36LALH / AJYA45LALH / AJYA54LALH<br />

650<br />

154<br />

(Unit : mm)<br />

Easy to read 7-segment LED : Confirm detail operational<br />

and trouble status without using specific equipment<br />

Error status can be checked easily via the indoor unit wired<br />

controller. An error code is displayed on a liquid crystal<br />

screen.<br />

Wired Remote Controller<br />

370<br />

43(Liquid)<br />

51(Gas)<br />

(410)<br />

40<br />

Faulty unit number (Remote controller address)<br />

Error code<br />

32<br />

36<br />

970 32 370 12<br />

7-segment LED<br />

Terminal blocks (Transmission)<br />

SU MO TU WE TH FR SA<br />

Terminal blocks (Power)<br />

Simple Remote Controller<br />

1334<br />

Remote controller address<br />

3-Way valve (Liquid)<br />

907<br />

1000<br />

Movable PCB panel<br />

Easier for maintenance work<br />

behind the PCB<br />

Error code<br />

21<br />

Ø28 (Cable port)<br />

131<br />

87<br />

89<br />

3-Way valve (Gas)<br />

Ø28 (Cable port)<br />

25<br />

50 95<br />

Pipe port<br />

279<br />

(Liquid valve)<br />

297<br />

(Gas valve)<br />

120<br />

111<br />

155<br />

50<br />

142<br />

70<br />

Ø28 (Cable port)<br />

21 55<br />

Ø28 (Cable port)<br />

Pipe port<br />

21 65<br />

50<br />

Ø28 (Cable port)<br />

Ø28 (Cable port)<br />

Pipe port<br />

Emergency Stop Function<br />

341<br />

305<br />

227<br />

A<br />

65 15<br />

50 14<br />

Detail<br />

A<br />

Emergency alarm can be received by indoor,<br />

outdoor units, Central Remote Controller or<br />

Touch Panel Controller when they received it,<br />

all units will be stopped.<br />

Note : In case of received Emergency alarm by<br />

Indoor / outdoor unit : All units connected within<br />

same refrigerant system will be stopped.<br />

Central Remote Controller or Touch Panel<br />

Controller : all units connected within VRF network<br />

system with Central Remote Controller or Touch<br />

Panel Controller will be stopped.<br />

Trouble diagnosis by Service Tool<br />

Connection to Service Tool<br />

• Detail operation status and recent error history can be<br />

checked and analyzed by using Service Tool.<br />

• Last 5 min. operation memory can be also recorded.<br />

Central<br />

Remote Controller<br />

or<br />

Touch Panel<br />

Controller<br />

Emergency<br />

stop function<br />

Emergency<br />

stop function<br />

Transmission cable (Non-polar 2 wires)<br />

Service Tool<br />

UTY-ASGX Software<br />

USB adaptor (Field supplied)<br />

Emergency<br />

stop function<br />

Specifications<br />

Rating Capacity range<br />

Model name<br />

Maximum Connectable Indoor Unit<br />

Indoor unit connectable capacity Cooling<br />

Power source<br />

Capacity<br />

Input power<br />

EER<br />

COP<br />

Air flow rate<br />

Sound<br />

pressure level<br />

Compressor motor output<br />

Heat exchanger fin<br />

Dimensions<br />

50<br />

Weight<br />

Refrigerant charge<br />

Connection<br />

pipe diameter<br />

Operation<br />

range<br />

438<br />

622<br />

HP<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

High<br />

Cooling<br />

Heating<br />

Height<br />

Width<br />

Depth<br />

kW<br />

kW<br />

kW<br />

kW<br />

W/W<br />

m 3 /h<br />

dB<br />

(A)<br />

mm<br />

mm<br />

mm<br />

kg<br />

kg<br />

Liquid<br />

mm<br />

Gas<br />

Cooling<br />

˚C<br />

Heating<br />

4<br />

AJYA36LALH<br />

6<br />

5.6 to 14.5<br />

Single-phase, ~230V, 50Hz<br />

11.2<br />

12.5<br />

2.80<br />

2.76<br />

4.00<br />

4.53<br />

6,200<br />

50<br />

52<br />

3.75<br />

Blue fin<br />

1,334<br />

970<br />

370<br />

117<br />

4.8<br />

ø9.52<br />

ø15.88<br />

-5 to 46<br />

-20 to 21<br />

Pipe & cable port<br />

5<br />

AJYA45LALH<br />

8<br />

7.0 to 18.2<br />

Single-phase, ~230V, 50Hz<br />

14.0<br />

16.0<br />

3.89<br />

3.81<br />

3.60<br />

4.20<br />

6,400<br />

51<br />

53<br />

3.75<br />

Blue fin<br />

1,334<br />

970<br />

370<br />

117<br />

5.3<br />

ø9.52<br />

ø15.88<br />

-5 to 46<br />

-20 to 21<br />

6<br />

AJYA54LALH<br />

9<br />

7.8 to 20.1<br />

Single-phase, ~230V, 50Hz<br />

15.5<br />

18.0<br />

4.49<br />

4.56<br />

3.45<br />

3.95<br />

6,900<br />

53<br />

55<br />

3.75<br />

Blue fin<br />

1,334<br />

970<br />

370<br />

117<br />

5.3<br />

ø9.52<br />

ø19.05<br />

-5 to 46<br />

-20 to 21<br />

Equipment Detail (Diagram)<br />

Note : Specifications are based on the following conditions.<br />

Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.<br />

Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.<br />

Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.<br />

The protective function might work when using it outside the operation range.<br />