RAINWATER HARVESTING KITS - INSTALLATION MANUAL<br />

Pump and pipework installation<br />

(i) Float switch assembly<br />

Assemble the float switch onto the stainless steel mounting<br />

bracket then mount and position the bracket on the pump body<br />

using the large hose clip as shown in figure 11. Do not<br />

overtighten the clip.<br />

USW200 requires the 4mm bore level sensing tube and sleeved<br />

grommet to be fitted to the bracket, as shown.<br />

Secure the float switch cable and sensing tube (where fitted) to<br />

the pump cable with cable ties every 300mm.<br />

(ii) Discharge hose assembly<br />

Apply a few turns of thread tape to the 25mm hose adaptor and<br />

fit to the outlet of the pump, then secure the discharge hose<br />

with the hose clip.<br />

Tie the pump withdrawal <strong>co</strong>rd to the eyelet on the pump body<br />

and lower the assembly into the well.<br />

Both <strong>co</strong>ntrol systems require a length of 15mm Equator push-fit<br />

pipe to run from the discharge hose fitting to the wall tap or<br />

<strong>co</strong>nnection point for the header tank.<br />

Note: the Equator pipe can be used to assist in feeding the<br />

electrical cables and tubing through the service pipe to the<br />

<strong>co</strong>ntrol housing – refer to page 12 before proceeding.<br />