<strong>OPTIMA</strong> <strong>System</strong> – Solutions for ISOVER Multi-Comfort House*<br />
Today’s modern housing needs to provide much more than basic shelter from the elements – it must offer high standards of quality and<br />
safety throughout. Just as high standards of energy efficiency have now become the norm, families today require a comfortable thermal<br />
environment all year round, and excellent acoustic protection from both internally and externally generated noise. Equally important are<br />
issues such as fire protection and the longevity of the property – and, of course the quality of the internal air within the building.<br />
To address these challenges, ISOVER has developed and refined its Multi-Comfort House concept to offer the ultimate combination of<br />
solutions to meet the demands of modern living.<br />
Supporting wall 25 cm cellular concrete with Wood frame house**** 20 cm glued bricks with 14 cm<br />
8 cm existing insulation (R = 4.8) composite thermal insulation system<br />
(wall R = 4.4) (R = 4.6)<br />
Facing 12.5 mm plaster board 12.5 mm plaster board 12.5 mm plaster board<br />
ISOVER Glass Thickness: 160 mm Thickness: 160 mm Thickness: 160 mm<br />
Wool Product R = 5 m 2 K/W R = 5 m 2 K/W R = 5 m 2 K/W<br />
λd = 0.032 W/(mK) λd = 0.032 W/(mK) λd = 0.032 W/(mK)<br />
U-Value* 0.10 W/(m 2 .K) 0.10 W/(m 2 .K) 0.10 W/(m 2 .K)<br />
Total thickness wall + lining = 510 mm*** wall + lining = 380 mm*** wall + lining = 520 mm***<br />
of construction<br />
* The shown examples of the U-values fullfil criteria of ISOVER Multi-Comfort House for single family houses in moderate climate.<br />
** Calculations were made with TRISCO software, version 10.0w ©2002 PHYSIBEL, conform with existing standards.<br />
*** Air gap of 7.5 mm; the insulation material is compressed flush to the vertical studs.<br />
**** U-value calculation takes wooden frame into account.<br />
13