<strong>OPTIMA</strong> <strong>System</strong> – An efficient sound insulation<br />
For acoustic comfort indoors, a house needs to be well insulated against the noise outside. The<br />
<strong>OPTIMA</strong> <strong>System</strong>, based on the mass-spring-mass principle, achieves ISOVER Acoustic Comfort<br />
Classes, which generally exceed standard requirements for sound insulation. The <strong>OPTIMA</strong> <strong>System</strong><br />
safeguards personal privacy in the home, maintaining the well-being of its occupants.<br />
Acoustic insulation of a construction is determined by the (weighted) sound reduction index Rw,<br />
expressed in dB: the higher the Rw, the better the sound insulation.<br />
The table below shows some examples of sound reduction for different types of support walls,<br />
insulation and facing materials. Important: sound reduction of 10 dB causes 50% reduction of the<br />
parceived noise!<br />
Thickness of ISOVER Support +<br />
Support glass wool with Facing Support only <strong>OPTIMA</strong> Gain<br />
AFr ≥ 5 kPa.s/m 2 Rw (C;Ctr) in dB Rw (C;Ctr) in dB Rw+C in dB<br />
Hollow concrete<br />
blocks 200 mm + glue<br />
100 mm Wood panelling 53 (-1 ; -2) 71 (-4 ; -11) 15<br />
Hollow concrete<br />
blocks 200 mm + glue<br />
100 mm PVC panelling 53 (-1 ; -2) 67 (-3 ; -11) 12<br />
Hollow concrete<br />
blocks 200 mm + glue<br />
100 mm<br />
12.5 mm<br />
Plaster board<br />
53 (-1 ; -2) 76 (-4 ; -11) 20<br />
Hollow concrete<br />
blocks 200 mm + glue<br />
75 mm<br />
12.5 mm<br />
Plaster board<br />
54 (-2 ; -4) 68 (-3 ; -10) 13<br />
Concrete 160 mm 85 mm<br />
12.5 mm<br />
Plaster board<br />
58 (-1 ; -4) 71 (-2 ; -6) 12<br />
Hollow bricks 200 mm<br />
+ glue<br />
100 mm<br />
12.5 mm<br />
Plaster board<br />
42 (0 ; -2) 68 (-2 ; -9) 24<br />
Hollow bricks 200 mm<br />
+ glue<br />
75 mm<br />
12.5 mm<br />
Plaster board<br />
50 (-5 ; -7) 66 (-3 ; -8) 18<br />
Plaster tile 70 mm 85 mm<br />
In multi-family buildings<br />
12.5 mm<br />
Plaster board<br />
35 (-1 ; -3) 57 (-1 ; -6) 22<br />
Sound absorbing elements installed on the walls (Picture 1) and ceilings can significantly reduce echo<br />
in hallways. The <strong>OPTIMA</strong> <strong>System</strong>, with a perforated facing is ideal for such situations.