Vacuum and Pothole - 50<br />
<strong>FX25</strong> Operator’s <strong>Manual</strong><br />
Pothole<br />
6. Adjust water pressure as needed to match soil conditions and/or material of utility being exposed.<br />
Jobsite hazards could cause death or serious injury. Use correct<br />
equipment and work methods. Use and maintain proper safety equipment.<br />
To help avoid injury: Test water pressure on a sample of the utility line material to be exposed.<br />
Adjust pressure until no damage occurs to the material. High pressure water can cut utility lines.<br />
7. Ensure that water sprays from nozzle in a fan pattern. If it does not, nozzle may be clogged and pump<br />
will not function properly. Clean or replace nozzle as necessary.<br />
8. When freshwater tank is empty, stop operation and turn water pump switch to off.<br />
NOTICE: Do not continue to operate with freshwater tank empty. Running water pump with no<br />
water will damage pump.<br />