Service - 74<br />
<strong>FX25</strong> Operator’s <strong>Manual</strong><br />
10 Hour<br />
Check Water Pump Belt Tension<br />
Check belt every 10 hours for correct tension,<br />
damage or wear. Contact your <strong>Ditch</strong> <strong>Witch</strong> dealer<br />
for adjustment or belt replacement.<br />
To check<br />
1. Turn ignition to STOP and remove key.<br />
2. Apply moderate thumb pressure to belt<br />
between pulleys.<br />
3. Belt is properly tensioned when deflection is<br />
.125-.25” (3-6 mm).<br />
4<br />
2<br />
j32om040h.eps<br />
Clean Vacuum Air Filter<br />
Breathing<br />
crystalline silica dust may cause<br />
lung disease. Cutting, drilling, or<br />
working materials such as<br />
concrete, sand, or rock<br />
containing quartz may result in exposure to<br />
silica dust. Use dust control methods or<br />
appropriate breathing protection when<br />
exposed to silica dust.<br />
Clean filter every 10 hours or as needed.<br />
To clean filter:<br />
j32om015h.eps<br />
1. Remove filter from canister.<br />
2. Run low pressure water into inside of filter.<br />
NOTICE: Do not use high pressure water to clean filter. Filter will be damaged.<br />
3. Allow filter to dry completely before returning to canister.<br />
CMW