<strong>FX25</strong> Operator’s <strong>Manual</strong> Service - 73<br />

10 Hour<br />

Check Blower Belt Tension<br />

Check belt every 10 hours for correct tension,<br />

damage or wear. Idler pulley tensioner should be<br />

set to 70 lb of force. Verify that the indication<br />

marks on tensioner are in the same position as<br />

initially set, or apply 10 lb of force to the belt and<br />

check that deflection is .25-.375” (6-10 mm).<br />

Check Water Pump Oil Level<br />

With frame level, check water pump oil at sight<br />

glass (2) every 10 hours. Add NDO at fill (1) as<br />

necessary to keep oil at halfway mark on sight<br />

glass.<br />

j32om037h.eps<br />

1<br />

2<br />

Clean Water Pump Filter<br />

j32om038h.eps<br />

Clean water pump filter every 10 hours and<br />

replace as needed.<br />

1. Open filter housing.<br />

2. Remove element and rinse housing<br />

thoroughly with water.<br />

3. Inspect element for signs of collapse and for<br />

brittle or broken rubber seals on the ends of<br />

the element. Replace as needed. See<br />

page 89.<br />

4. Replace element and close filter housing.<br />