FX25 Operator's Manual - Ditch Witch
FX25 Operator's Manual - Ditch Witch
FX25 Operator's Manual - Ditch Witch
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>FX25</strong> Operator’s <strong>Manual</strong> Service - 73<br />
10 Hour<br />
Check Blower Belt Tension<br />
Check belt every 10 hours for correct tension,<br />
damage or wear. Idler pulley tensioner should be<br />
set to 70 lb of force. Verify that the indication<br />
marks on tensioner are in the same position as<br />
initially set, or apply 10 lb of force to the belt and<br />
check that deflection is .25-.375” (6-10 mm).<br />
Check Water Pump Oil Level<br />
With frame level, check water pump oil at sight<br />
glass (2) every 10 hours. Add NDO at fill (1) as<br />
necessary to keep oil at halfway mark on sight<br />
glass.<br />
j32om037h.eps<br />
1<br />
2<br />
Clean Water Pump Filter<br />
j32om038h.eps<br />
Clean water pump filter every 10 hours and<br />
replace as needed.<br />
1. Open filter housing.<br />
2. Remove element and rinse housing<br />
thoroughly with water.<br />
3. Inspect element for signs of collapse and for<br />
brittle or broken rubber seals on the ends of<br />
the element. Replace as needed. See<br />
page 89.<br />
4. Replace element and close filter housing.<br />
j32om039h.eps<br />
CMW