29.12.2014 Views

FX25 Operator's Manual - Ditch Witch

FX25 Operator's Manual - Ditch Witch

FX25 Operator's Manual - Ditch Witch

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>FX25</strong> Operator’s <strong>Manual</strong> Vacuum and Pothole - 53<br />

Unload to Another Tank<br />

Unload to Another Tank<br />

Optional reverse flow mode can be used to transfer vacuumed material to another tank or disposal site.<br />

Incorrect procedures could result in death, injury, or property damage.<br />

Learn to use equipment correctly.<br />

To help avoid injury:<br />

• Keep unit in “vacuum” mode unless pressure is needed.<br />

• Restrain hose prior to pressurization. Unrestrained hose may cause property damage, injury or<br />

death.<br />

• Do not open fitting cams or valves when tank is pressurized. Flying debris, plugs and doors can<br />

cause injury or death.<br />

• Do not open tank door while tank is pressurized.<br />

• Do not use pressure to clear clogs in vacuum hose.<br />

IMPORTANT: Check relief valve as shown<br />

before each use.<br />

j33om059h.eps<br />

1. Throttle down completely and turn off engine. Securely connect transfer hose to FX tank. Ensure drain/<br />

outlet valve on FX tank is closed.<br />

2. Securely connect other end of transfer hose to offboard tank. Ensure inlet valve on offboard tank is<br />

closed and tank is vented.<br />

3. Open FX tank drain/outlet valve. Material will flow into transfer hose.<br />

4. Open offboard tank inlet valve.<br />

CMW

Hooray! Your file is uploaded and ready to be published.

Saved successfully!