1000 Hour<br />
<strong>FX25</strong> Operator’s <strong>Manual</strong><br />
1000 Hour<br />
Location Task Notes<br />
VACUUM<br />
SYSTEM<br />
Change blower oil<br />
Change hydraulic fluid<br />
SGL<br />
THF<br />
Vacuum System<br />
Change Blower Oil<br />
Change oil every 1000 hours. Change oil more<br />
frequently if working in dusty conditions.<br />
2<br />
• Drain at drain plug (4) while oil is warm.<br />
• Add SGL at fill (2) until oil is at halfway point<br />
on sight glass (3).<br />
4<br />
3<br />
j32om047h.eps<br />
CMW