Vacuum and Pothole - 54<br />
<strong>FX25</strong> Operator’s <strong>Manual</strong><br />
Unload to Another Tank<br />
5. Move valve handle counterclockwise to engage “reverse flow” mode and start engine. Material will flow<br />
into offboard tank.<br />
6. Increase throttle as desired to transfer material.<br />
7. When transfer is complete, throttle down completely and turn off engine. Close FX tank drain/outlet<br />
valve.<br />
8. Close offboard tank inlet valve and disconnect hose from offboard tank inlet valve.<br />
9. Move handle clockwise to “vacuum” mode and turn on engine.<br />
10. Open FX tank drain/outlet valve. Material will empty from transfer hose.<br />
11. Close FX tank drain/outlet valve, throttle down and turn off engine.<br />
12. Disconnect transfer hose from FX tank.<br />
CMW