Complete the Job - 58<br />

Antifreeze Fluid Excavation Unit<br />

<strong>FX25</strong> Operator’s <strong>Manual</strong><br />

Antifreeze Fluid Excavation Unit<br />

Add Antifreeze<br />

Follow these steps for overnight or long-term storage of unit during cold weather.<br />

1. Fill antifreeze tank with a propylene-glycol based antifreeze.<br />

2. Ensure that water tank valve is closed.<br />

3. Open antifreeze tank valve.<br />

4. Connect water pressure hose to water lance.<br />

5. Start engine.<br />

6. Move water pump switch to on. If freshwater tank is empty, move to bypass.<br />

7. Squeeze water lance handle and run until antifreeze runs through the water lance.<br />

8. Move water pump switch to off.<br />

9. Close antifreeze tank supply valve.<br />

10. Turn ignition switch to off.<br />

11. Drain water tank completely.<br />

Reclaim Antifreeze<br />

1. Turn water pressure down.<br />

2. Move water pump switch to on.<br />

3. Put end of water lance in antifreeze tank.<br />

4. Squeeze water lance handle and run until water comes out of lance.<br />

5. Move water pump switch to off.<br />