You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>MIRAGE</strong> Service Manual <strong>Carefree</strong> <strong>of</strong> <strong>Colorado</strong><br />
D03A AWNING DOES NOT AUTO-RETRACT IN WIND (STANDARD ELECTRONICS)<br />
NOTE: For standard electronics with the optional auto-retract anemometer; the auto-retract system is always on.<br />
Confirm that the sensitivity is set correctly (if set on highest level, system may appear not to function). Setting the<br />
sensitivity is in the Owner's manual and on page 26.<br />
A<br />
B<br />
Confirm that the retract function works using the PATIO<br />
switch<br />
YES<br />
NO<br />
Function works using the switch; go to<br />
test B<br />
Function does not work with switch; go<br />
to procedure D01<br />
Test Anemometer<br />
1 Do the anemometer cups spin freely YES Go to step B2<br />
NO Anemometer defective - replace<br />
2 Test signal from anemometer:<br />
YES Control Box is defective - replace<br />
2.1 Remove anemometer wires from control box;<br />
NO The circuit stays open or stays closed;<br />
2.2 Place continuity tester between anemometer<br />
go to step B3<br />
wires;<br />
2.3 Have a helper slowly turn the anemometer:<br />
Does the circuit open and close It should open<br />
and close once for every revolution.<br />
3 Test the wire continuity between the control box and the YES Continuity OK; replace anemometer<br />
anemometer.<br />
NO Repair or Replace wires as required<br />
D03B AWNING DOES NOT AUTO-RETRACT IN WIND (DIRECT RESPONSE)<br />
A<br />
Press the power on button then press the auto-retract button.<br />
Does the auto-retract LED flash<br />
YES<br />
NO<br />
The flashing LED indicates that the<br />
sensor has been disengaged or<br />
otherwise disabled. Go to step C.<br />
Function does not work with switch;<br />
go to procedure D01<br />
B Confirm that the retract function works using the push buttons. YES Function works using the switch; go<br />
to test C<br />
NO Function does not work with switch;<br />
go to procedure D01<br />
C Test Motion Sensor<br />
1 Confirm cable is plugged into connector on box marked YES Go to step 2<br />
“Shaker”<br />
NO Correct as required and test.<br />
2 2.1 Unplug sensor from control box.<br />
2.2 Connect a second sensor into control box.<br />
2.3 Set the control switches for the auto retract function<br />
2.4 Hold the second sensor horizontally and gently move<br />
up and down.<br />
YES<br />
NO<br />
Awning retracts; original sensor<br />
defective - replace<br />
Awning does not retract; control box<br />
defective - replace<br />
12 052979-301r6