Test Case: Switch Flow Failover Performance Test<br />

6. Go to Interfacees tab and assign the interface previously created under<br />

protocol interface. This interface is used for the control-plane (OF Channel).<br />

Configure Number of Channels as 1.<br />

7. Go to OF Channels tab and enter DUT IP address in Remote IP field. Enter<br />

Number of Flow Ranges as 2.<br />

8. Under Flow Ranges tab, configure Ethernet Type, Source and Destination IP<br />

address. Use wild card (*) for remaining all fields. Use same IP address for both<br />

ranges. Configure correct In Port field with the switch port number that is<br />

connected to <strong>Ixia</strong> host port generating traffic.<br />

Figure 44: Flow Ranges tab<br />

PN 915-2635-01 Rev A December 2012 48