Manual USDT Revsion 8 - Thermomax Technologies
Manual USDT Revsion 8 - Thermomax Technologies
Manual USDT Revsion 8 - Thermomax Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>USDT</strong> 2001 OPERATION<br />
OPERATION<br />
Y our controller displays requested information one at a time.<br />
Selection indicator and its value blinks interchanged on unit’s<br />
display window. Push selection key (yellow) once to move to the next<br />
selection. Change set value by pressing the Set-Up (blue) key.<br />
NOTE: Holding selection key for two seconds brings the controller in<br />
advance programming mode.<br />
Collector temperature display<br />
Tank temperature display<br />
Press Set-Up key to increase T<br />
Factory Setting è 9.0 o F<br />
Range è 1 o F to 50 o F<br />
(Set Hysteresis value H1X, in advance mode, to<br />
H11 for smaller T values)<br />
Press Set-Up key for pump operation<br />
mode<br />
Aut è Automatic Mode<br />
On è Pump manually actvated<br />
OFF è Pump manually in off position<br />
Press Set-Up key to increase tank over<br />
heating protection temperature. Pump<br />
stops when tank temperature exceeds<br />
this value.<br />
Factory setting è 160 o F<br />
Range è 32 o F to 200 o F<br />
8<br />
Thermo <strong>Technologies</strong>