Manual USDT Revsion 8 - Thermomax Technologies
Manual USDT Revsion 8 - Thermomax Technologies
Manual USDT Revsion 8 - Thermomax Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>USDT</strong> 2001 INTRODUCTION<br />
Introduction<br />
Note: The information supplied in this manual is for guidance only - no<br />
part of this may be used for any agreement, whether express or implied,<br />
or to form any contract. Thermo <strong>Technologies</strong> reserves the right to<br />
change specifications without prior notice.<br />
T<br />
he <strong>USDT</strong> 2001 unit is designed to control a simple solar water<br />
heating system. By using microprocessor technology it ensures<br />
that the collected energy from the sun is transferred efficiently<br />
and harnessed under optimum conditions. It monitors collector<br />
temperature (T C ) and return temperature (T T , bottom of the storage<br />
tank). The solar loop circulation pump runs while the collector<br />
temperature exceeds the return temperature by a programmable<br />
temperature difference T. To avoid overheating, the circulation pump<br />
stops if the tank (T T ) temperature reaches the programmable high limit<br />
(T MAX ) temperature. To prevent freezing, the controller activates the<br />
pump and circulates water through the solar loop when frost conditions<br />
exist. The temperature hysteresis (a lagging in the set-point) may override<br />
T and can be modified in advanced operation mode to avoid pump<br />
cycling.<br />
The control unit has the following functions:<br />
• 2 inputs for temperature sensors<br />
• Suitable for sensors of type Thermistor and PT1000<br />
• All hysteresises are adjustable and depend on temperature<br />
• Adjustable (0 o F - 50 o F) frost protection<br />
• Adjustable (32 o F - 200 o F) overheating protection<br />
• Adjustable (1 o F – 50 o F) temperature difference T<br />
• <strong>Manual</strong> override of pump for system testing<br />
• Digital display of collector, tank, T, and maximum tank<br />
temperature<br />
• Indications of current state of pump<br />
• Surge protection at collector sensor<br />
1<br />
Thermo <strong>Technologies</strong>