Title 16 - BUILDING AND CONSTRUCTION ... - King County
Title 16 - BUILDING AND CONSTRUCTION ... - King County
Title 16 - BUILDING AND CONSTRUCTION ... - King County
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>16</strong>.14.500 Exterior structure - Insect screens. Section 304.14 of the International Property<br />
Maintenance Code is not adopted. (Ord. 14914 § 409, 2004).<br />
<strong>16</strong>.14.510 Exterior structure - Building security. Section 304.18 and all of the subsections<br />
thereto of the International Property Maintenance Code are not adopted. (Ord. 14914 § 410, 2004).<br />
<strong>16</strong>.14.520 Water system - General. Section 505.1 of the International Property Maintenance<br />
Code is not adopted and the following is substituted:<br />
General (IPMC 505.1). Every sink, lavatory, bathtub or shower, drinking fountain, water closet or<br />
other plumbing fixture shall be properly connected to either a public water system or to an approved<br />
private water system. All kitchen sinks, lavatories, laundry facilities, bathtubs and showers shall be<br />
supplied with hot or tempered and cold running water in accordance with K.C.C. chapter <strong>16</strong>.32. (Ord.<br />
14914 § 412, 2004: Ord. 14111 § 137, 2001: Ord. 12560 § 114, 1996. Formerly K.C.C. <strong>16</strong>.<strong>16</strong>.090;<br />
<strong>16</strong>.04.050111).<br />
<strong>16</strong>.14.530 Heating facilities - Residential occupancies. Section 602.2 of the International<br />
Property Maintenance Code is not adopted. (Ord. 14914 § 413, 2004).<br />
<strong>16</strong>.14.540 Heating facilities - Heat supply. Section 602.3 of the International Property<br />
Maintenance Code is not adopted and the following is substituted:<br />
Heat supply (IPMC 602.3). Dwellings units and guest rooms shall be provided with heating<br />
facilities capable of maintaining a room temperature of 70° F. (21.1° C), bathrooms and toilet rooms.<br />
Cooking appliances shall not be used to provide space heating to meet the requirements of this section.<br />
(Ord. 14914 § 415, 2004: Ord. 14111 § 138, 2001: Ord. 12560 § 115, 1996. Formerly K.C.C. <strong>16</strong>.<strong>16</strong>.100;<br />
<strong>16</strong>.04.050112).<br />
<strong>16</strong>.14.550 Heating facilities – Occupiable work spaces. Section 602.4 of the International<br />
Property Maintenance Code is not adopted. (Ord. 14914 § 4<strong>16</strong>, 2004).<br />
<strong>16</strong>.14.560 Heating facilities – Room temperature measurement. Section 602.5 of the<br />
International Property Maintenance Code is not adopted and the following is substituted:<br />
Room temperature measurement (IPMC 602.5). The required room temperatures shall be<br />
measured three feet (.914 m) above the floor near the center of the room and two feet (610 mm) inward<br />
from the center of each exterior wall. (Ord. 14914 § 417, 2004).<br />
<strong>16</strong>.14.570 Electrical facilities - Service. Section 604.2 of the International Property<br />
Maintenance Code is not adopted. (Ord. 14914 § 418, 2004).<br />
<strong>16</strong>.14.580 Electrical equipment - Receptacles. Section 605.2 of the International Property<br />
Maintenance Code is not adopted. (Ord. 14914 § 419, 2004).<br />
<strong>16</strong>.14.590 Elevators, escalators and dumbwaiters. Section 606 of the International Property<br />
Maintenance Code is not adopted. (Ord. 14914 § 420, 2004).<br />
<strong>16</strong>.32 KING COUNTY PLUMBING CODE<br />
Sections:<br />
<strong>16</strong>.32.030 Adoption of Uniform Plumbing Code.<br />
<strong>16</strong>.32.050 Enforcement.<br />
<strong>16</strong>.32.080 Fees - permit fees - double permit fee requirements - fees for reinspection service -<br />
refund of permit fees.<br />
<strong>16</strong>.32.085 Gas piping permit and inspection fees.<br />
<strong>16</strong>.32.095 Inspection outside working hours fee - permit applications after nonpermitted work fees<br />
double, permit required - reinspection fees - refunds if work not started.<br />
<strong>16</strong>.32.170 Board of appeals.<br />
<strong>16</strong>.32.175 Scope.<br />
<strong>16</strong>.32.185 Additions, Alterations or Repairs.<br />
<strong>16</strong>.32.195 Authority Having Jurisdiction.<br />
<strong>16</strong>.32.205 Right of Entry.<br />
<strong>16</strong>.32.215 Stop Work Order and Correction Order.<br />
<strong>16</strong>.32.225 Authority to Correct Hazardous or Insanitary Plumbing.