RS-485 User's Manual MEH448d - Fuji Electric America
RS-485 User's Manual MEH448d - Fuji Electric America
RS-485 User's Manual MEH448d - Fuji Electric America
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Model Communications<br />
means<br />
FRENIC<br />
-Mini<br />
FRENIC<br />
Table 2.2 Connection method and applicable protocol for FRENIC series<br />
<strong>RS</strong>-<strong>485</strong><br />
communications<br />
card (option)<br />
Inverter-keypad<br />
coupling<br />
connector<br />
-Eco*4 <strong>RS</strong>-<strong>485</strong><br />
communications<br />
card (option)<br />
Inverter-keypad<br />
coupling<br />
connector<br />
FRENIC<br />
-Multi <strong>RS</strong>-<strong>485</strong><br />
communications<br />
card*4 (option)<br />
FRENIC<br />
-MEGA<br />
Inverter-keypad<br />
coupling<br />
connector<br />
Standard port<br />
Connection<br />
port<br />
RJ-45<br />
connector<br />
RJ-45<br />
connector<br />
Terminal<br />
block<br />
RJ-45<br />
connector<br />
RJ-45<br />
connector<br />
for function<br />
expansion<br />
(2 pc)<br />
RJ-45<br />
connector<br />
Terminal<br />
block<br />
Hardware<br />
specifications<br />
for connection<br />
port<br />
See 2.1.1.<br />
See 2.1.1.<br />
2-2<br />
Applicable protocol *1<br />
Port type Keypad*2 Loader Modbus<br />
RTU*3<br />
Standard<br />
port<br />
Standard<br />
port<br />
See 2.1.2. Extension<br />
port<br />
See 2.1.1.<br />
Standard<br />
port<br />
See 2.1.3. Extension<br />
port<br />
See 2.1.1.<br />
Standard<br />
port<br />
See 2.1.2. Extension<br />
port<br />
<strong>Fuji</strong><br />
general-purpose<br />
inverter protocol<br />
� � � �<br />
� � � �<br />
× × � �<br />
� � � �<br />
× × � �<br />
� � � �<br />
× × � �<br />
*1 The protocol support ranges such as keypad monitoring items, loader functions, and accessible<br />
function codes differ depending on the inverter type. For details, see the instruction manual for<br />
each protocol.<br />
*2 The applicable keypad depends on the inverter type.<br />
Series<br />
Remote keypad<br />
TP-E1 TP-M1 TP-E1U<br />
Multi-function keypad<br />
TP-G1 TP-G1-J1<br />
FRENIC-Mini � × × × ×<br />
FRENIC-Eco � × × � �<br />
FRENIC-Multi × � × � �<br />
FRENIC-MEGA × × � × �<br />
*3 The Modbus RTU used for FRENIC-Mini does not support the coil commands. See "Chapter 3<br />
Modbus RTU PROTOCOL " for details.<br />
*4 N2 Protocol is applicable only with FRN□□F1□-□A, FRN□□F1□-□C, FRN□□F1□-□E and<br />
FRN□□F1□-□U. Refer to INR-SI47-1322-E