RAIN MASTER TM EAGLE PLUS<br />

Setting the Usage Option<br />

1. Turn the Dial to choose the USAGE option. The<br />

FLOW 1 ONLY option is selected by default.<br />

Press the Dial to select.<br />

2. Turn the Dial to display the preferred option<br />

(FLOW 1, FLOW 2, FLOW 1 & 2 or NONE).<br />

Press the Dial to enter the selection.<br />

3. Turn the Dial to choose the MORE option or<br />

press the Next key.<br />

SETUP FLOW:<br />

SENSORS -ENABLED -<br />

USAGE[FLOW1 ONLY ]<br />

-MORE-<br />

SETUP FLOW:<br />

SENSORS -ENABLED -<br />

USAGE[FLOW2 ONLY]<br />

-MORE-<br />

SETUP FLOW:<br />

SENSORS -ENABLED -<br />

USAGE-FLOW2 ONLY-<br />

[MORE]<br />

Setting the Standard/Custom Sensor Options<br />

1. The SETUP FLOW menu is displayed with the<br />

SENSORS option chosen by default. Press the<br />

Dial to select SENSORS.<br />

2. The SETUP FLOW SENSOR screen is displayed,<br />

with the sensor number option chosen by<br />

default. Press the Dial to select, then turn the<br />

Dial to display SENSOR 1 or 2. Press the Dial to<br />

enter the selection.<br />

3. Turn the Dial to choose the STANDARD for<br />

<strong>Rain</strong> <strong>Master</strong> flow sensor or CUSTOM for alternate<br />

flow sensor makes. Press the Dial to select.<br />

SETUP FLOW:<br />

[SENSOR] -DELAY-<br />

–LIMITS– –LEARN–<br />

–TOTALIZER–<br />

SETUP FLOW SENSOR[2]<br />

TYPE:<br />

–STANDARD- -CUSTOM-<br />

• For <strong>Rain</strong> <strong>Master</strong> Flow Sensors:<br />

4. The sensor SIZE option is chosen. Press the Dial<br />

to select, then turn the Dial to display the actual<br />

sensor size. Press the Dial to enter the selection.<br />

• For Alternate Flow Sensors:<br />

4. The sensor OFFSET value option is chosen by<br />

default. Press the Dial to select, then turn the<br />

Dial to display the preferred value (0–999).<br />

Press the Dial to enter the selection.<br />

5. Turn the Dial to choose the K value. Press the<br />

Dial to select, then turn the Dial to display the<br />

preferred value (0–32767). Press the Dial to<br />

enter the selection.<br />

SETUP FLOW SENSOR 2<br />

SIZE[ 2.00 INCH ]<br />

SETUP FLOW SENSOR 2<br />

OFFSET=[109]<br />

K=- 0-<br />

SETUP FLOW SENSOR-2-<br />

TYPE:<br />

[STANDARD] -CUSTOM-<br />

SETUP FLOW SENSOR 2<br />

OFFSET=-109-<br />

K=[ 779]<br />

26 Selecting Flow Sensor Setup and Operation Preferences