Sanitary pumps
Sanitary pumps
Sanitary pumps
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Contra<br />
<strong>Sanitary</strong> <strong>pumps</strong><br />
Contra<br />
The design fulfils the following requirements:<br />
• QHD criteria<br />
• EHEDG recommendations.<br />
• GOST sanitary standard (Russia).<br />
GR8961<br />
Fig. 7<br />
Contra<br />
Contra I and II<br />
Technical data<br />
Head:<br />
up to 160 m<br />
Flow rate: up to 55 m 3 /h<br />
Operating pressure:<br />
up to 25 bar<br />
Operating temperature: 95 °C<br />
(up to 150 °C on request)<br />
Sterilisation temperature: 140 °C (SIP)<br />
Applications<br />
The unique hygienic design and the materials used make<br />
the Contra <strong>pumps</strong> suitable for these applications:<br />
Food and beverage industry<br />
• breweries and dairies<br />
• carbonising systems<br />
• food processing plants.<br />
Pharmaceutical and related industries<br />
• purification systems<br />
• pure-water systems (WFI)<br />
• personal care.<br />
Other industrial applications<br />
• surface treatment systems<br />
• water processing systems<br />
• CIP feeding systems.<br />
Fig. 8<br />
Certification<br />
The <strong>pumps</strong> comply with these surface finish requirements:<br />
Standard pump version: 3A1<br />
Optional: 3A2, 3A3.<br />
For explanation, see section Certification, page 55.<br />
The pump housing is made of rolled and forged stainless<br />
steel to DIN EN 1.4404/1.4435, the equivalent of AISI<br />
316L. This guarantees a homogeneous, pore-free surface,<br />
in contrast to cast materials.<br />
The Contra <strong>pumps</strong> have open diffusers. The design<br />
ensures that O-ring seals for pump housing and impeller<br />
are located to meet the criteria of hygenic design with<br />
metal-to-metal contact and that there are no dead ends<br />
in the pump housing.<br />
Contra <strong>pumps</strong> are fitted with a semi-open impeller as<br />
standard. See page 51.<br />
The vertical versions are fully self-draining through the<br />
suction port of the <strong>pumps</strong>.<br />
The <strong>pumps</strong> have a mechanical shaft seal and a fancooled<br />
asynchronous motor to enclosure class IP55.<br />
1 4 5 6<br />
Construction<br />
Contra single-stage or multi-stage, end-suction centrifugal<br />
<strong>pumps</strong> are designed to meet the hygienic requirements<br />
of sterile process technology.<br />
The <strong>pumps</strong> are available in a variety of flexible versions.<br />
The <strong>pumps</strong> are CIP and SIP capable in compliance with<br />
the DIN EN 12462 performance criteria. They also meet<br />
the GMP requirements regarding FDA-approved materials.<br />
Fig. 9<br />
2 3 7<br />
Sectional drawing of Contra I Bloc-SUPER on combi<br />
foot<br />
TM02 9610 3504<br />
10