<strong>Sanitary</strong> <strong>pumps</strong><br />

Contra<br />

The design fulfils the following requirements:<br />

• QHD criteria<br />

• EHEDG recommendations.<br />

• GOST sanitary standard (Russia).<br />

GR8961<br />

Fig. 7<br />

Contra<br />

Contra I and II<br />

Technical data<br />

Head:<br />

up to 160 m<br />

Flow rate: up to 55 m 3 /h<br />

Operating pressure:<br />

up to 25 bar<br />

Operating temperature: 95 °C<br />

(up to 150 °C on request)<br />

Sterilisation temperature: 140 °C (SIP)<br />

Applications<br />

The unique hygienic design and the materials used make<br />

the Contra <strong>pumps</strong> suitable for these applications:<br />

Food and beverage industry<br />

• breweries and dairies<br />

• carbonising systems<br />

• food processing plants.<br />

Pharmaceutical and related industries<br />

• purification systems<br />

• pure-water systems (WFI)<br />

• personal care.<br />

Other industrial applications<br />

• surface treatment systems<br />

• water processing systems<br />

• CIP feeding systems.<br />

Fig. 8<br />

Certification<br />

The <strong>pumps</strong> comply with these surface finish requirements:<br />

Standard pump version: 3A1<br />

Optional: 3A2, 3A3.<br />

For explanation, see section Certification, page 55.<br />

The pump housing is made of rolled and forged stainless<br />

steel to DIN EN 1.4404/1.4435, the equivalent of AISI<br />

316L. This guarantees a homogeneous, pore-free surface,<br />

in contrast to cast materials.<br />

The Contra <strong>pumps</strong> have open diffusers. The design<br />

ensures that O-ring seals for pump housing and impeller<br />

are located to meet the criteria of hygenic design with<br />

metal-to-metal contact and that there are no dead ends<br />

in the pump housing.<br />

Contra <strong>pumps</strong> are fitted with a semi-open impeller as<br />

standard. See page 51.<br />

The vertical versions are fully self-draining through the<br />

suction port of the <strong>pumps</strong>.<br />

The <strong>pumps</strong> have a mechanical shaft seal and a fancooled<br />

asynchronous motor to enclosure class IP55.<br />

1 4 5 6<br />

Construction<br />

Contra single-stage or multi-stage, end-suction centrifugal<br />

<strong>pumps</strong> are designed to meet the hygienic requirements<br />

of sterile process technology.<br />

The <strong>pumps</strong> are available in a variety of flexible versions.<br />

The <strong>pumps</strong> are CIP and SIP capable in compliance with<br />

the DIN EN 12462 performance criteria. They also meet<br />

the GMP requirements regarding FDA-approved materials.<br />

Fig. 9<br />

2 3 7<br />

Sectional drawing of Contra I Bloc-SUPER on combi<br />

foot<br />

TM02 9610 3504<br />

10