Installation<br />
<strong>Sanitary</strong> <strong>pumps</strong><br />
Mechanical installation<br />
Never install the pump with the motor pointing downwards.<br />
Horizontal installation<br />
• Pumps fitted with motors up to and including 4 kW<br />
require a 300 mm clearance behind the motor.<br />
See fig. 44.<br />
• Pumps fitted with motors of 5.5 kW and up require<br />
a 300 mm clearance behind and a 1 metre clearance<br />
above the motor to allow the use of lifting equipment.<br />
See fig. 44.<br />
TM03 0113 4004<br />
0.55-4 kW<br />
Fig. 42 Installation<br />
300 mm<br />
The <strong>pumps</strong> must be installed in such a way that strain<br />
from the pipework is not transferred to the pump<br />
housing.<br />
When installed outdoors, the motor must be provided<br />
with a suitable cover to avoid condensation on the<br />
electronic components and to protect pump and motor<br />
against the direct effects of the elements.<br />
5.5-30 kW<br />
1 m<br />
Space requirements<br />
Vertical installation<br />
• Pumps fitted with motors up to and including 4 kW<br />
require a 300 mm clearance above the motor.<br />
See fig. 43.<br />
• Pumps fitted with motors of 5.5 kW and up require at<br />
least a 1 metre clearance above the motor to allow<br />
the use of lifting equipment. See fig. 43.<br />
Fig. 44 Horizontal installation<br />
300 mm<br />
0.55-4 kW 5.5-30 kW<br />
300 mm 1 m<br />
TM03 0114 4004<br />
TM03 0115 4004<br />
Fig. 43 Vertical installation<br />
57