19.01.2015 Views

Sanitary pumps

Sanitary pumps

Sanitary pumps

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Curve charts<br />

<strong>Sanitary</strong> <strong>pumps</strong><br />

Curve conditions<br />

The guidelines below apply to the curves shown on the<br />

following pages:<br />

1. Tolerances to ISO 9906, Annex A.<br />

1 kW < P2 < 10 kW<br />

Flow rate: ±9 %<br />

Total head: ±7 %<br />

Efficiency: up to –7 % *<br />

* Efficiency of motor sizes below 10 kW are calculated on the<br />

basis of a formula stated in ISO 9906.<br />

P2 > 10 kW<br />

Flow rate: ±8 %<br />

Total head: ±5 %<br />

Efficiency: –5 %<br />

2. QH curves of the individual <strong>pumps</strong> are shown with<br />

expected speed of a three-phase standard motor.<br />

3. Measurements have been made with airless water at<br />

a temperature of +20 °C.<br />

4. The curves apply to the following kinematic viscosity:<br />

υ = 1 mm 2 /s (1 cSt).<br />

5. If the pumped liquid density and/or viscosity is<br />

higher than that of water, it may be necessary to use<br />

a motor with a higher performance.<br />

60

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!