Troubleshooting, Cont.<br />

I. Excess or Insufficient Output Pressure<br />

• Inspect the control hoses, connectors, shuttle valves <strong>and</strong><br />

adapters. Replace as necessary.<br />

• Rotate the adjustment screw atop of the pilot valve. Rotate<br />

clockwise to increase pressure or counterclockwise to reduce<br />

pressure as necessary.<br />

• Remove <strong>and</strong> clean the finger strainer. Replace if necessary.<br />

• If this fails to balance the pressure, try the following procedure:<br />

- Unscrew <strong>and</strong> remove the throttle housing (12) at the<br />

bottom of the pilot valve.<br />

- Remove the throttle pin (14) from inside the housing.<br />

- Wrap the throttle pin (14) with Teflon tape <strong>and</strong> re-insert<br />

it into the housing.<br />

- Re-insert <strong>and</strong> tighten the throttle housing into the pilot<br />

• Replace the pilot valve.<br />

J. Excess or Insufficient Input Pressure<br />

• Inspect the control hoses, connectors, shuttle valves <strong>and</strong> adapters. Tighten <strong>and</strong> replace as<br />

necessary.<br />

• Remove <strong>and</strong> clean the finger strainer. Replace if necessary.<br />

• Repair or replace the pilot valve.<br />

K. Excess or Insufficient Flow Rate<br />

• Inspect the control hoses, connectors, shuttle valves <strong>and</strong><br />

adapters.<br />

• Tighten <strong>and</strong> replace as necessary.<br />

• Rotate the adjustment screw on the top of the pilot valve.<br />

Rotate clockwise to increase flow rate or counterclockwise<br />

to reduce the flow rate as necessary.<br />

• Clean <strong>and</strong> check the orifice <strong>and</strong> gaskets. Replace as<br />

necessary.<br />

• Remove <strong>and</strong> clean the finger strainer. Replace if necessary.<br />

• If this fails to balance the pressure, try the following<br />

procedure:<br />

- Unscrew <strong>and</strong> remove the throttle housing (12) at the<br />

bottom of the pilot valve.<br />

- Remove the throttle pin (14) from inside the<br />

housing.<br />

- Wrap the throttle pin (14) with Teflon tape <strong>and</strong><br />

re-insert it into the pilot valve.<br />

• Replace the pilot valve.<br />