<strong>Maintenance</strong> 3” <strong>and</strong> 4” Models, Cont.<br />
INLET SPIDER AND STRAINER<br />
Dis-assembly<br />
• Loosen <strong>and</strong> remove the impeller bushing (36), the inlet<br />
spider bearing nut (35) <strong>and</strong> the inlet spider bearing<br />
washer (34).<br />
• Remove the inlet spider tube (33).<br />
• Inspect the inlet spider o-ring (32) <strong>and</strong> replace as<br />
necessary.<br />
Re-assembly<br />
• Replace the inlet spider tube (33)<br />
• Replace the inlet spider bearing washer (34) <strong>and</strong> nut<br />
(35) onto the inlet spider shaft (31) <strong>and</strong> tighten.<br />
• Replace the impeller bushing (36) into the inlet spider<br />
nut (35).<br />
<strong>Hydrometers</strong> <strong>Operation</strong> <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong> • 31