<strong>Maintenance</strong> 3” <strong>and</strong> 4” Models<br />

HYDROMETER DIS-ASSEMBLY AND RE-<br />

ASSEMBLY<br />

Dis-assembly of the 3” <strong>and</strong> 4” hydrometer is divided into the following<br />

assemblies:<br />

• Cover Assembly<br />

• Diaphragm/Stem <strong>and</strong> Base Assemblies<br />

• Inlet Spider/Strainer Assembly<br />

Perform only those steps necessary to inspect <strong>and</strong> replace parts as directed<br />

by the troubleshooting procedures. It is recommended to replace the<br />

various<br />

o-rings <strong>and</strong> gaskets during dis-assembly as well as to inspect certain<br />

other parts. All gaskets <strong>and</strong> o-rings must be covered with grease prior to<br />

installation.<br />

HYDROMETER COVER AND BASE SUB-<br />

ASSEMBLIES<br />

Removal<br />

• Remove the register subassembly as described on page 24.<br />

• Loosen <strong>and</strong> remove the cover screws (10) along with the washers.<br />

• Lift the cover off of the hydrometer body (29). Be especially careful<br />

not to damage the impeller.<br />

• Carefully remove the impeller assembly (37) from the hydrometer<br />

body.<br />

• Inspect the impeller <strong>and</strong> its components for signs of excessive wear<br />

or damage. Verify that the impeller shaft is straight. Replace as<br />

necessary.<br />

• Inspect the base o-ring (42) for excessive wear or damage. Replace as<br />

necessary.<br />

Re-assembly<br />

• Insert the impeller (37) into the inlet spider (located inside the<br />

hydrometer base).<br />

• Insert the base “O” ring (42) into the groove on the upper body flange.<br />

• Carefully place the cover over the impeller shaft (37) <strong>and</strong> onto the<br />

hydrometer body (29).<br />

• Replace <strong>and</strong> tighten the cover screws (10).<br />

• Replace the register subassembly as described on page 24.<br />

<strong>Hydrometers</strong> <strong>Operation</strong> <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong> • 29