<strong>Maintenance</strong> 3” <strong>and</strong> 4” Models<br />
HYDROMETER DIS-ASSEMBLY AND RE-<br />
ASSEMBLY<br />
Dis-assembly of the 3” <strong>and</strong> 4” hydrometer is divided into the following<br />
assemblies:<br />
• Cover Assembly<br />
• Diaphragm/Stem <strong>and</strong> Base Assemblies<br />
• Inlet Spider/Strainer Assembly<br />
Perform only those steps necessary to inspect <strong>and</strong> replace parts as directed<br />
by the troubleshooting procedures. It is recommended to replace the<br />
various<br />
o-rings <strong>and</strong> gaskets during dis-assembly as well as to inspect certain<br />
other parts. All gaskets <strong>and</strong> o-rings must be covered with grease prior to<br />
installation.<br />
HYDROMETER COVER AND BASE SUB-<br />
ASSEMBLIES<br />
Removal<br />
• Remove the register subassembly as described on page 24.<br />
• Loosen <strong>and</strong> remove the cover screws (10) along with the washers.<br />
• Lift the cover off of the hydrometer body (29). Be especially careful<br />
not to damage the impeller.<br />
• Carefully remove the impeller assembly (37) from the hydrometer<br />
body.<br />
• Inspect the impeller <strong>and</strong> its components for signs of excessive wear<br />
or damage. Verify that the impeller shaft is straight. Replace as<br />
necessary.<br />
• Inspect the base o-ring (42) for excessive wear or damage. Replace as<br />
necessary.<br />
Re-assembly<br />
• Insert the impeller (37) into the inlet spider (located inside the<br />
hydrometer base).<br />
• Insert the base “O” ring (42) into the groove on the upper body flange.<br />
• Carefully place the cover over the impeller shaft (37) <strong>and</strong> onto the<br />
hydrometer body (29).<br />
• Replace <strong>and</strong> tighten the cover screws (10).<br />
• Replace the register subassembly as described on page 24.<br />
<strong>Hydrometers</strong> <strong>Operation</strong> <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong> • 29