<strong>Maintenance</strong> 1½” <strong>and</strong> 2” Models, Cont.<br />

INLET SPIDER AND STRAINER<br />

Dis-assembly<br />

• Loosen the impeller bushing (29) located atop the inlet<br />

spider screw (24) <strong>and</strong> bushing (28). Pull the entire inlet<br />

spider screw assembly up <strong>and</strong> out.<br />

• Pull the inlet spider (27) upward <strong>and</strong> remove it from the<br />

hydrometer body (21). Inspect for cracks or excessive<br />

wear <strong>and</strong> replace as necessary.<br />

• Remove <strong>and</strong> replace the body o-ring (26).<br />

• Remove the strainer (25). Clean <strong>and</strong> inspect for damage or<br />

excessive wear.<br />

• Replace as necessary.<br />

Re-assembly<br />

• Place the body o-ring (26) in the small flange inside the<br />

hydrometer base.<br />

• Place the strainer (25) into the hydrometer base.<br />

• Insert the inlet spider into the body so that the end rests on<br />

the top of the strainer <strong>and</strong> the flange rests over the body<br />

o-ring (26).<br />

• Place the inlet spider screw assembly through the holes<br />

in the input spider (27) <strong>and</strong> strainer (25). Use a socket<br />

wrench to tighten the impeller bushing (29) atop the<br />

assembly.<br />

28 • <strong>Hydrometers</strong> <strong>Operation</strong> <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong>